Cutting AI Datacenter Energy with Reinforcement Learning: Measured Power Control of LLM Training from One GPU to the Fleet

arXiv cs.AI Papers

Summary

A new arXiv paper explores using reinforcement learning to reduce AI datacenter energy consumption by dynamically controlling power for LLM training workloads across scales from a single GPU to entire fleets.

arXiv:2608.11226v1 Announce Type: new Abstract: Reinforcement-learning post-training dominates modern language-model development, yet its power behavior on GPU hardware has not been characterized, and datacenters manage GPU power with workload-blind mechanisms, static caps and reactive throttling, that slow hardware indiscriminately. We instrument GRPO training with half-second power telemetry at 7B, 14B, and 72B scales on one to four A100s (380,000+ samples), and train a PPO meta-controller that adapts the workload's own generation parameters to measured power. Against the full 500-step 7B trace, the controller cuts power-limit violations by 89.8% while increasing token output by 18.1% and energy efficiency by 26.2% (tokens per MWh). Deployed live at 72B, the same controller family yields replicated null results, diagnosed as the group-size actuator losing authority under model sharding. An actuator-authority sweep shows the same parameters applied as generation concurrency retain 17-22% power authority, isolating an occupancy-versus-volume principle; a controller rebuilt on that actuator controls a live 72B rollout-generation workload across three replications: 35.7% more output than a static safe baseline at 2.27 +/- 1.08% budget violations, 87.2% fewer violations than uncontrolled operation, and the best mean throughput and energy per token among constrained controllers, with an adaptive threshold rule matching it in one of three operating conditions. Under realistic measurement windows the original 72B transients fall from 23.6% at half-second resolution to 1.6% at 30 s and zero at 5 min; a composed 16-GPU fleet shows zero violations at 30 s and longer, with peak demand at 50-56% of nameplate. For this fleet mix, roughly twofold oversubscription of nameplate appears feasible, subject to operator validation. We quantify the economic and carbon consequences and specify a low-cost operator pilot.
Original Article
View Cached Full Text

Cached at: 08/13/26, 03:22 PM

# Cutting AI Datacenter Energy with Reinforcement Learning: Measured Power Control of LLM Training from One GPU to the Fleet
Source: [https://arxiv.org/abs/2608.11226](https://arxiv.org/abs/2608.11226)
Bibliographic Tools

## Bibliographic and Citation Tools

Bibliographic Explorer Toggle

Code, Data, Media

## Code, Data and Media Associated with this Article

Demos

## Demos

Related Papers

## Recommenders and Search Tools

About arXivLabs

## arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website\.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy\. arXiv is committed to these values and only works with partners that adhere to them\.

Have an idea for a project that will add value for arXiv's community?[**Learn more about arXivLabs**](https://info.arxiv.org/labs/index.html)\.

Similar Articles

AI-driven Thermal-aware Data Center Capacity Planning

arXiv cs.LG

An arXiv paper presents an AI-driven framework for thermal-aware data center capacity planning that predicts temperatures in milliseconds, achieving high accuracy on unseen designs with a 10,000x speedup over high-fidelity CFD simulations, enabling real-time optimization of workload distribution and HVAC cooling for LLM-driven data centers.

AI At Home Part 2: Multi GPU Drifting

Lobsters Hottest

The article explores optimizing AI language model performance on a home server built from e-waste GPUs, with explanations of transformer models and multi-GPU techniques.