大语言模型在患者证据演变过程中更新临床判断的可靠性不足
摘要
研究评估了大语言模型在患者证据随时间演变时更新临床判断的可靠性,发现模型存在对恶化证据反应过度、受先验判断因果影响等失败模式,并提出EVLU方法来识别更可靠但覆盖更少的判断修订,确立了纵向信念更新作为LLM可靠性的独立评估维度。
arXiv:2610.02684v1 Announce Type: new
Abstract: Large language models (LLMs) are increasingly explored for clinical reasoning, but whether they appropriately revise judgments as patient evidence evolves remains unclear. We evaluated longitudinal belief updating using matched intensive-care trajectories from electronic health records. Across diverse LLMs, conditioning on a preceding judgment more often increased than reduced prediction error when estimates changed, replicated for a second endpoint. Controlled interventions revealed two failure modes. First, with preceding assessment fixed, models responded more strongly to worsening than matched improving respiratory evidence; this asymmetry persisted after headroom normalization at moderate and strong evidence levels. Second, with current evidence fixed, increasing prior risk from 10% to 90% shifted estimates by 26.2 percentage points, demonstrating causal influence of prior model beliefs. Prompting did not restore reliable updating. Evidence-Validated Longitudinal Update (EVLU) identified fewer, more reliable revisions, revealing a reliability-coverage trade-off. These findings establish longitudinal belief updating as a distinct dimension of LLM reliability.
查看缓存全文
缓存时间: 2026/10/05 09:59
# Large language models exhibit unreliable updating of clinical judgment as patient evidence evolves Source: [https://arxiv.org/html/2610.02684](https://arxiv.org/html/2610.02684) Min ZengAffiliation:Division of Computational Health Sciences, Department of Surgery, University of Minnesota, Minneapolis, 55455, MN, USARui ZhangEmail:[ruizhang@umn\.edu](mailto:[email protected])Affiliation:Division of Computational Health Sciences, Department of Surgery, University of Minnesota, Minneapolis, 55455, MN, USA ###### Abstract Large language models \(LLMs\) are increasingly explored for clinical reasoning, but whether they appropriately revise judgments as patient evidence evolves remains unclear\. We evaluated longitudinal belief updating using matched intensive\-care trajectories from electronic health records\. Across diverse LLMs, conditioning on a preceding judgment more often increased than reduced prediction error when estimates changed, replicated for a second endpoint\. Controlled interventions revealed two failure modes\. First, with preceding assessment fixed, models responded more strongly to worsening than matched improving respiratory evidence; this asymmetry persisted after headroom normalization at moderate and strong evidence levels\. Second, with current evidence fixed, increasing prior risk from 10% to 90% shifted estimates by 26\.2 percentage points, demonstrating causal influence of prior model beliefs\. Prompting did not restore reliable updating\. Evidence\-Validated Longitudinal Update \(EVLU\) identified fewer, more reliable revisions, revealing a reliability–coverage trade\-off\. These findings establish longitudinal belief updating as a distinct dimension of LLM reliability\. ## Introduction Large language models \(LLMs\) have demonstrated strong capabilities across medical question answering, clinical knowledge assessment, diagnostic reasoning, summarization, and decision support[Singhal et al\. \(2023\)](https://arxiv.org/html/2610.02684#bib.bib2);[Thirunavukarasu et al\. \(2023\)](https://arxiv.org/html/2610.02684#bib.bib15);[Van Veen et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib16);[Singhal et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib7), motivating increasing interest in their integration into clinical workflows\. However, much of the supporting evidence still comes from evaluations that treat model outputs as isolated decisions\. A systematic review of healthcare LLM evaluations found that only a small minority used real patient\-care data and that accuracy remained the dominant evaluation dimension[Bedi et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib3)\. Such evaluations characterize what a model concludes at a particular point in time, but clinical care is inherently longitudinal: patient physiology evolves, new evidence accumulates, and assessments that were appropriate at one time point may need to be maintained, strengthened, or revised as the clinical state changes\. Recent work has moved beyond static medical question answering toward sequential clinical evaluation\. Clinician\-generated EHR tasks, simulated clinical interactions, and stepwise diagnostic workflows have revealed limitations not apparent from examination\-style accuracy alone[Fleming et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib18);[Johri et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib17);[Hager et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib4);[Rao et al\. \(2026\)](https://arxiv.org/html/2610.02684#bib.bib8), while performance can vary with the quantity or order of clinical information[Hager et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib4)\. Studies of longitudinal electronic health records further suggest that longer clinical histories do not necessarily yield reliable temporal reasoning[Fleming et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib18);[Kruse et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib9);[Cui et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib19)\. Thus, strong performance on static or aggregate clinical benchmarks does not establish whether models can appropriately revise clinical judgments as patient evidence evolves\. Longitudinal use introduces an additional challenge: once a model has generated a clinical assessment, that assessment may itself become part of the context for subsequent reasoning\. This can provide useful continuity, but also creates a pathway through which previous model assessments may influence later judgments beyond what current patient evidence supports\. More generally, language models have been shown to struggle with belief revision when new information requires modification of an earlier conclusion[Wilie et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib5), to exhibit sensitivity to prior user positions and contextual framing[Sharma et al\. \(2023\)](https://arxiv.org/html/2610.02684#bib.bib23);[Mahajan et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib6);[Sheppert et al\. \(2026\)](https://arxiv.org/html/2610.02684#bib.bib10), and, in conflicting\-context settings, to preferentially rely on model\-generated context even when external context is more reliable[Tan et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib20)\. Multi\-turn evaluations have further identified susceptibility to error propagation across conversational turns[Kwan et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib21)\. An appropriate longitudinal clinical reasoner should preserve a preceding judgment when it remains supported, revise it when contradicted by new evidence, and adjust the magnitude of revision according to the strength of that evidence\. Failure to do so could allow inaccurate assessments to propagate across time or produce systematically different responses to clinically comparable evidence of deterioration and recovery\. Existing evaluations do not disentangle evolving patient evidence from the model’s preceding judgment because both change together during clinical trajectories\. Complementary controlled interventions are therefore needed to independently manipulate each source of longitudinal context: manipulating newly presented clinical evidence while holding the preceding model judgment fixed, and independently manipulating the preceding judgment while holding the current clinical evidence unchanged\. Such a design can distinguish evidence\-responsive updating from dependence induced by model\-generated history and identify longitudinal updating patterns that are invisible to conventional snapshot\-level evaluation\. Here, we systematically characterize longitudinal clinical belief updating in LLMs using matched intensive\-care trajectories derived from electronic health records\. We use “belief” operationally to denote the model’s expressed clinical assessment or risk estimate, without implying human\-like mental states\. We compare independent assessments with longitudinal assessments conditioned on the model’s preceding judgment across diverse general\-purpose and medically adapted LLMs, with cross\-endpoint replication for vasopressor initiation\. Paired controlled interventions separately manipulate evolving respiratory evidence and the supplied preceding model belief, characterizing directional evidence responsiveness and causally isolating prior\-belief influence\. Finally, we test evidence\-first and anti\-anchoring prompting and introduce an Evidence\-Validated Longitudinal Update \(EVLU\) strategy that retains context\-induced revisions only when corroborated by evolving objective respiratory evidence\. Together, these experiments identify longitudinal belief updating as a distinct dimension of LLM reliability: model\-generated beliefs and evolving patient evidence are not interchangeable forms of context\. ## Results ### Construction of a matched longitudinal clinical cohort We constructed a matched longitudinal ICU cohort from MIMIC\-IV[Johnson et al\. \(2023\)](https://arxiv.org/html/2610.02684#bib.bib1)\(Fig\.[1](https://arxiv.org/html/2610.02684#Sx2.F1)\)\. The cohort comprised 1,000 ventilation\-positive ICU stays and 1,000 negative stays matched on sex, first ICU care unit and age\. The 2,000 unique patients contributed 6,580 clinical snapshots \(mean, 3\.29 per stay\)\. All positive\-stay snapshots preceded invasive ventilation, preventing incorporation of post\-outcome information\. This cohort supported natural longitudinal evaluation and controlled evidence interventions\. Figure 1:Study design for evaluating longitudinal clinical belief updating as patient evidence evolves\.a, Construction of the matched longitudinal ICU cohort, comprising 1,000 ventilation\-positive ICU stays and 1,000 matched negative ICU stays\.b, Longitudinal clinical states were represented by sequential snapshots after ICU admission, with the model estimating the risk of invasive mechanical ventilation within the subsequent 24 h at each snapshot\.c, Natural longitudinal evaluation compared predictions based on the current clinical state alone with predictions additionally conditioned on the model’s preceding assessment\.d, Controlled interventions independently manipulated evolving respiratory evidence and the supplied preceding model belief while holding the complementary source of information fixed, enabling characterization of directional evidence responsiveness and the causal influence of supplied prior beliefs\.e, Mitigation analyses tested instruction\-level prompting and evidence validation; prompting did not eliminate harmful longitudinal updating, whereas EVLU preferentially retained a smaller subset of more reliable revisions at reduced coverage\. Icon attributions are provided in Table S1\. ### Longitudinal self\-context more often worsens than improves paired prediction accuracy We first examined whether access to the model’s preceding assessment altered subsequent risk estimates under naturally evolving clinical trajectories \(Fig\.[1](https://arxiv.org/html/2610.02684#Sx2.F1)c\)\. Across 4,580 post\-initial snapshots, longitudinal predictions were 9\.50 percentage points higher than independent predictions of the same current clinical state on average, with a mean absolute difference of 14\.90 percentage points\. These context\-induced changes did not improve predictive performance\. Across all 6,580 snapshots, AUROC was 0\.545 under independent evaluation and 0\.541 under longitudinal evaluation, while Brier score increased from 0\.281 to 0\.284 \(Fig\.[2](https://arxiv.org/html/2610.02684#Sx2.F2)a\)\. At the paired\-snapshot level, longitudinal context increased absolute prediction error in 46\.20% of cases, reduced it in 30\.28%, and left it unchanged in 23\.52% \(Fig\.[2](https://arxiv.org/html/2610.02684#Sx2.F2)b\), increasing mean absolute error by 3\.62 percentage points\. Thus, self\-context substantially altered subsequent predictions but was more likely to impair than improve their accuracy\. a b c Figure 2:Longitudinal self\-context alters clinical risk estimates and produces harmful paired effects across model families\.a, Predictive performance under independent and longitudinal evaluation for the primary model, measured by AUROC and Brier score across 6,580 clinical snapshots\.b, Effect of longitudinal self\-context on absolute prediction error across 4,580 post\-initial snapshots\. Longitudinal context increased prediction error more frequently than it reduced error\.c, Cross\-model generalization of harmful longitudinal\-context effects across eight evaluated models\. Left, change in mean absolute prediction error under longitudinal relative to independent inference\. Right, normalized harmful\-update asymmetry between harmful and beneficial accuracy\-changing effects; positive values indicate a greater frequency of harmful than beneficial effects among accuracy\-changing predictions\. Error bars in the right panel indicate 95% confidence intervals obtained by bootstrap resampling at the ICU\-stay level\. ### Harmful longitudinal dependence replicates in hemodynamic deterioration We next tested whether harmful longitudinal dependence generalized from respiratory to hemodynamic deterioration\. We independently constructed a second matched cohort for 24\-h prediction of continuous vasopressor initiation, comprising 1,000 vasopressor\-positive and 1,000 matched vasopressor\-negative ICU stays\. The cohort yielded 6,444 serial assessments evaluated using the same longitudinal protocol as for invasive ventilation\. The central pattern replicated closely\. Across 4,444 post\-initial assessments, longitudinal context increased absolute prediction error in 46\.7% of cases, reduced it in 28\.8%, and left it unchanged in 24\.5%\. Mean absolute prediction error increased by 3\.44 percentage points \(95% CI, 2\.62–4\.24\), while predicted risk shifted upward by 10\.03 percentage points \(95% CI, 9\.33–10\.76\)\. This paired degradation occurred despite a modest increase in aggregate discrimination \(AUROC, 0\.574 to 0\.582\), showing that improved aggregate ranking can coexist with less reliable longitudinal updating\. Thus, harmful longitudinal dependence replicated across independently constructed respiratory and hemodynamic deterioration cohorts\. ### Harmful longitudinal dependence generalizes across model families We tested whether harmful longitudinal dependence generalized beyond the primary Qwen3\-8B model by repeating the independent\-versus\-longitudinal evaluation across eight general\-purpose and medically adapted models spanning the Qwen, Llama, Mistral, MedGemma, and Gemma families \(4B–32B parameters\)\. All models used the same 2,000\-patient cohort, clinical timelines, prediction target, and inference protocol\. Mean absolute prediction error increased by 0\.4–3\.6 percentage points under longitudinal relative to independent inference in all eight models \(Fig\.[2](https://arxiv.org/html/2610.02684#Sx2.F2)c; Table S2\)\. Aggregate discrimination was less consistent: AUROC decreased in six models but increased slightly in MedGemma\-27B\-Text\-IT and Gemma\-3\-12B\-IT\. Thus, aggregate ranking performance did not reliably track effects on paired prediction accuracy\. Among post\-initial snapshots whose prediction accuracy changed, the harmful fraction exceeded 50% in every model \(52\.63–60\.41%\)\. Normalized harmful\-update asymmetry was correspondingly positive across all eight models \(0\.053–0\.208\), with 95% confidence intervals excluding zero in every case \(Fig\.[2](https://arxiv.org/html/2610.02684#Sx2.F2)c; Table S3\)\. Normalized harmful\-update asymmetry decreased from 0\.208 to 0\.137 between Qwen3\-8B and Qwen3\-32B and from 0\.163 to 0\.064 between the two evaluated Mistral scales, but increased from 0\.130 to 0\.154 between MedGemma\-4B\-IT and MedGemma\-27B\-Text\-IT\. Thus, although effect magnitude varied across model families and scales, larger models did not consistently attenuate harmful longitudinal dependence\. ### Belief revision is directionally appropriate and dose\-responsive to controlled evolving evidence We next tested whether the model revised its beliefs appropriately in response to controlled changes in respiratory evidence \(Fig\.[1](https://arxiv.org/html/2610.02684#Sx2.F1)d\)\. Of 4,580 real longitudinal transitions, 4,545 contained the respiratory measurements required for intervention construction\. For each eligible transition, we held the preceding context and prior model assessment fixed while introducing worsening or improving respiratory evidence at subtle, moderate, or strong intensities\. Worsening evidence increased mean predicted risk by 16\.43, 30\.86, and 45\.21 percentage points under subtle, moderate, and strong perturbations, respectively, with directionally appropriate increases in 97\.32–99\.85% of transitions \(Fig\.[3](https://arxiv.org/html/2610.02684#Sx2.F3)a\)\. Improving evidence decreased mean predicted risk by 11\.66, 18\.72, and 25\.55 percentage points, respectively, with directionally appropriate decreases in 86\.84–91\.90% of transitions\. Revision magnitude increased monotonically with evidence strength in 99\.93% of worsening transitions and 97\.58% of improving transitions\. Thus, belief revision tracked both the direction and strength of evolving evidence, providing a basis for testing whether update magnitude was symmetric between deterioration and improvement\. a b c Figure 3:Controlled respiratory evidence produces selective, dose\-dependent, and directionally asymmetric belief revision\.a, Mean change in predicted 24\-h invasive ventilation risk following worsening and improving evidence at subtle, moderate, and strong intervention strengths\.b, Raw directional asymmetry across evidence strengths\. Asymmetry was defined as the excess magnitude of deterioration\-directed relative to improvement\-directed belief revision; positive values indicate stronger updating in response to worsening evidence\.c, Mean absolute changes in predicted ventilation risk under neutral and redundant control interventions compared with clinically informative improving and worsening interventions\. Neutral and redundant evidence elicited little revision on average\. Error bars ina–cindicate 95% confidence intervals obtained by bootstrap resampling at the ICU\-stay level\. ### Belief updating exhibits strength\-dependent directional asymmetry On the raw probability scale, worsening evidence produced larger belief revisions than matched improving evidence at all three intervention strengths\. Mean raw asymmetry increased from 4\.78 percentage points for subtle evidence \(95% CI, 4\.21–5\.34\) to 12\.14 percentage points for moderate evidence \(95% CI, 11\.02–13\.26\) and 19\.65 percentage points for strong evidence \(95% CI, 17\.86–21\.44\) \(Fig\.[3](https://arxiv.org/html/2610.02684#Sx2.F3)b\)\. Thus, although both directions showed dose\-responsive revision, worsening evidence elicited progressively larger updates than matched improving evidence as evidence strength increased\. ### Directional asymmetry persists after accounting for probability headroom and preceding prediction error A potential explanation for the raw directional asymmetry is that upward and downward revisions are mechanically constrained by the preceding risk estimate\. We therefore normalized each revision by the available probability headroom in its corresponding direction\. After headroom normalization, subtle evidence showed a small improvement\-directed asymmetry \(−0\.030\-0\.030; 95% CI,−0\.039\-0\.039to−0\.021\-0\.021\), whereas moderate and strong evidence retained deterioration\-directed asymmetry of 0\.061 \(95% CI, 0\.051–0\.071\) and 0\.158 \(95% CI, 0\.147–0\.169\), respectively \(Fig\.[4](https://arxiv.org/html/2610.02684#Sx2.F4)a\)\. Thus, unequal probability headroom contributed to the raw asymmetry under weak evidence but did not explain the stronger response to moderate and strong worsening evidence\. Under strong evidence, deterioration\-directed asymmetry remained positive across all four ascending prior\-risk strata \(0\.324, 0\.046, 0\.036, and 0\.067, respectively; Fig\.[4](https://arxiv.org/html/2610.02684#Sx2.F4)b\), arguing against a simple ceiling\- or floor\-effect explanation\. a b c Figure 4:Directional asymmetry persists after accounting for prior belief headroom and preceding prediction error\.a, Directional asymmetry after normalizing worsening and improving revisions by the available upward and downward probability ranges, respectively\. Moderate and strong evidence retained deterioration\-directed asymmetry after normalization\.b, Headroom\-normalized asymmetry under strong evidence stratified by the preceding predicted ventilation risk\. Positive asymmetry persisted across all four prior\-risk strata\.c, Headroom\-normalized asymmetry under strong evidence stratified by the absolute error of the preceding risk estimate\. Positive asymmetry persisted across low, intermediate, and high prediction\-error strata, including transitions with relatively accurate preceding predictions\. Error bars indicate 95% bootstrap confidence intervals obtained by resampling at the ICU\-stay level\.We next stratified transitions by the absolute error of the preceding risk estimate\. Under strong evidence, headroom\-normalized asymmetry remained positive across low\-, intermediate\-, and high\-error strata \(0\.299, 0\.035, and 0\.144, respectively; Fig\.[4](https://arxiv.org/html/2610.02684#Sx2.F4)c\), including transitions with relatively accurate preceding predictions\. Because absolute prediction error is related to both the preceding probability estimate and observed outcome, we additionally stratified by outcome\. Deterioration\-directed asymmetry remained positive across all six outcome\-by\-error strata, with 95% bootstrap confidence intervals excluding zero \(Table S4\)\. The asymmetry was also evident at the individual\-transition level\. Under strong evidence, worsening perturbations produced greater proportional revision than matched improving perturbations in 66\.82% of transitions, whereas 27\.46% showed the opposite pattern and 5\.72% showed equal updating\. Together, these analyses show that directional asymmetry was not explained by preceding prediction error or outcome composition and was broadly distributed across individual transitions\. ### Neutral and redundant evidence elicit little belief revision on average We next tested whether belief revision was specific to clinically informative evidence rather than a generic response to additional context\. Across the same 4,545 eligible transitions used for the directional perturbations, neutral evidence produced no change in predicted risk, whereas redundant evidence produced a mean absolute revision of 0\.74 percentage points and no numerical change in 96\.99% of transitions \(Fig\.[3](https://arxiv.org/html/2610.02684#Sx2.F3)c\)\. In contrast, worsening and improving evidence elicited substantially larger revisions\. Thus, substantial belief updating was not a generic consequence of appending additional context, but occurred predominantly in response to clinically meaningful changes in respiratory evidence\. ### Directional asymmetry is consistent across clinical outcome groups We further examined whether the full strength\-dependent pattern of directional asymmetry was preserved across clinical outcome groups\. Under strong evidence, headroom\-normalized asymmetry remained deterioration\-directed in both ventilation\-positive and ventilation\-negative trajectories \(0\.124 and 0\.192, respectively\)\. Moreover, both outcome groups showed a similar strength\-dependent transition from a small improvement\-directed asymmetry under subtle evidence to increasingly deterioration\-directed asymmetry as evidence strengthened \(Table S5\)\. Thus, strength\-dependent directional asymmetry was not restricted to patients who ultimately required invasive ventilation\. ### Controlled prior\-belief interventions causally shift subsequent risk estimates Because prior assessments and evolving clinical evidence co\-occur in natural trajectories, these analyses cannot isolate whether the prior belief itself causally influences the subsequent prediction\. We therefore performed a controlled prior\-belief intervention in which the current clinical evidence was held fixed while the supplied prior ventilation risk was manipulated to 10%, 30%, 50%, 70%, or 90%\. Manipulating the supplied prior produced a strong dose\-dependent shift in subsequent risk estimates \(Fig\.[5](https://arxiv.org/html/2610.02684#Sx2.F5)a\)\. Across 4,574 post\-initial snapshots with complete five\-condition interventions, each 10\-percentage\-point increase in supplied prior risk increased the updated 24\-h ventilation\-risk estimate by 3\.05 percentage points \(95% CI, 3\.01–3\.10\), while increasing the supplied prior from 10% to 90% shifted the updated prediction by 26\.18 percentage points \(95% CI, 25\.74–26\.61\)\. Updated predictions were monotonically non\-decreasing across the five prior\-risk levels in 70\.4% of snapshots \(95% CI, 68\.9–71\.9%\)\. Thus, despite identical current clinical evidence, subsequent risk estimates remained systematically sensitive to the supplied prior belief\. This susceptibility had substantial consequences when the supplied prior was inconsistent with the observed outcome \(Fig\.[5](https://arxiv.org/html/2610.02684#Sx2.F5)b; Table S6\)\. Outcome\-misaligned extreme priors produced a mean absolute error of 0\.588, compared with 0\.326 under outcome\-aligned priors, corresponding to an absolute\-error increase of 0\.262 on the 0–1 probability scale \(95% CI, 0\.257–0\.266\)\. Because these paired conditions differed only in the supplied prior while holding the current clinical evidence fixed, these results provide direct evidence that supplied prior beliefs causally influence subsequent clinical risk estimates and can increase prediction error when misleading\. The controlled prior\-belief effect independently replicated in the hemodynamic deterioration cohort, with current hemodynamic evidence held fixed\. Across 4,440 post\-initial snapshots with complete five\-condition interventions, each 10\-percentage\-point increase in supplied prior risk increased the updated 24\-h vasopressor\-risk estimate by 2\.89 percentage points \(95% CI, 2\.84–2\.93\), while increasing the supplied prior from 10% to 90% produced a 24\.48\-percentage\-point difference in updated risk \(95% CI, 24\.06–24\.89\)\. Updated predictions were monotonically non\-decreasing across the five prior\-risk levels in 75\.0% of snapshots \(95% CI, 73\.5–76\.5%\)\. Outcome\-misaligned extreme priors increased absolute prediction error by 0\.245 on the 0–1 probability scale \(95% CI, 0\.241–0\.249\) relative to outcome\-aligned priors\. The close agreement in effect magnitude across respiratory and hemodynamic endpoints indicates that susceptibility to supplied prior belief was not specific to mechanical\-ventilation prediction \(Fig\. S1; Table S6\)\. Figure 5:Controlled prior\-belief interventions causally shift subsequent clinical risk estimates\.a, Dose–response relationship between the experimentally manipulated prior 24\-h ventilation risk and the subsequent updated risk estimate while current clinical evidence was held fixed\. Points indicate mean updated risk estimates and error bars indicate ICU\-stay\-level bootstrap 95% confidence intervals\.b, Mean absolute prediction error under outcome\-aligned and outcome\-misaligned extreme prior beliefs\. For outcome\-negative snapshots, 10% and 90% priors were treated as aligned and misaligned, respectively; for outcome\-positive snapshots, 90% and 10% priors were treated as aligned and misaligned, respectively\. Error bars indicate ICU\-stay\-level bootstrap 95% confidence intervals\. The annotated difference denotes the increase in mean absolute error for outcome\-misaligned relative to outcome\-aligned priors\. ### Simple prompting does not eliminate harmful longitudinal dependence Given the causal influence of supplied prior beliefs, we tested two instruction\-level mitigation strategies: an evidence\-first prompt requiring assessment of current clinical evidence before the previous assessment, and an anti\-anchoring prompt warning that the prior assessment could be inaccurate or outdated\. Both were evaluated across the 4,580 post\-initial snapshots used in the main longitudinal analysis with Qwen3\-8B, using independent predictions as the reference\. Neither strategy eliminated the harmful effects associated with longitudinal context \(Table S7\)\. Evidence\-first prompting reduced the mean prior\-directed shift by 1\.41 percentage points relative to the standard longitudinal prompt \(95% CI, 1\.05–1\.77\), but did not significantly reduce harmful\-update asymmetry \(Δ=−0\.005\\Delta=\-0\.005, 95% CI,−0\.027\-0\.027to 0\.017\) or mean absolute prediction error \(Δ=0\.07\\Delta=0\.07percentage points, 95% CI,−0\.23\-0\.23to 0\.36\)\. Anti\-anchoring prompting similarly reduced the mean prior\-directed shift by 1\.31 percentage points \(95% CI, 0\.95–1\.65\), but increased the proportion of snapshots harmed relative to independent prediction by 3\.95 percentage points \(95% CI, 2\.86–5\.08\) and increased mean absolute prediction error by 0\.39 percentage points \(95% CI, 0\.08–0\.69\)\. Thus, explicitly instructing the model to prioritize current evidence or discount potentially inaccurate prior assessments reduced attraction toward the prior but did not translate into more reliable longitudinal updating; anti\-anchoring instructions in fact increased both the proportion of snapshots harmed relative to independent prediction and mean absolute prediction error\. ### Evidence validation identifies more reliable longitudinal revisions We developed a label\-free evidence\-validated longitudinal update \(EVLU\) rule to selectively retain longitudinal context when its effect on prediction was supported by changing respiratory evidence\. For each post\-initial snapshot, we compared the direction of the longitudinal contextual correction—the difference between longitudinal and independent predictions—with respiratory evidence change based on SpO2, FiO2, oxygen flow, respiratory rate, PaO2, PaCO2, and pH, without using outcome labels\. The longitudinal prediction was retained only when its contextual correction was non\-zero and directionally concordant with respiratory evidence change; otherwise, the prediction reverted to the independent estimate\. Across 4,580 post\-initial snapshots, requiring an absolute net respiratory evidence score of at least one, concordant in direction with the contextual correction \(EVLU\-1\), reduced the harmful fraction among changed predictions to 58\.42% and normalized harmful\-update asymmetry to 0\.168\. Requiring an absolute net respiratory evidence score of at least two with the same directional concordance criterion \(EVLU\-2\) produced a larger reduction, lowering the harmful fraction to 46\.90% and reversing normalized harmful\-update asymmetry to−0\.062\-0\.062, while mean absolute error differed from independent prediction by only 0\.046 percentage points\. This gain in update reliability came at substantially reduced coverage: EVLU\-2 retained the longitudinal branch for 5\.63% of post\-initial predictions\. Relative to unrestricted longitudinal inference, EVLU\-2 reduced the harmful fraction among changed predictions by 13\.51 percentage points \(95% CI, 7\.55–19\.30\) and reduced normalized harmful\-update asymmetry by 0\.270 \(95% CI, 0\.151–0\.386\)\. To determine whether this greater reliability was explained solely by low longitudinal\-branch retention, we compared EVLU\-2 with matched random retention among the 3,503 nontrivial longitudinal revisions\. EVLU\-2 retained 258 revisions\. Across 10,000 randomizations retaining exactly 258 nontrivial revisions, the mean harmful fraction was 60\.40% \(95% randomization interval, 54\.65–65\.89%\), compared with 46\.90% under EVLU\-2 \(empiricalP<0\.001P<0\.001\)\. Revisions retained by EVLU\-2 also had a 14\.58\-percentage\-point lower harmful fraction than nontrivial revisions rejected by the gate \(95% CI, 8\.21–20\.92\) and a 4\.23\-percentage\-point smaller increase in absolute prediction error \(95% CI, 1\.35–7\.09\)\. Thus, the greater reliability of EVLU\-2\-retained revisions was not explained by reduced longitudinal\-context retention alone\. A stricter absolute net evidence threshold of three \(EVLU\-3\) yielded numerically more favorable update\-quality estimates, with a harmful fraction of 41\.56% and normalized harmful\-update asymmetry of−0\.169\-0\.169, while maintaining mean absolute error close to independent prediction\. However, EVLU\-3 retained only 1\.68% of post\-initial predictions, compared with 5\.63% under EVLU\-2, and the differences between EVLU\-3 and EVLU\-2 were not statistically distinguishable for harmful fraction, normalized harmful\-update asymmetry, or mean absolute error\. Together, these findings show that longitudinal context need not be discarded uniformly: restricting its influence to updates supported by concordant changes in objective clinical evidence improved the reliability of retained context\-induced revisions without requiring outcome labels or additional model inference, although at substantially reduced coverage\. Figure 6:Evidence validation identifies a more reliable subset of longitudinal updates\.a, Harmful fraction among accuracy\-changing predictions under unrestricted longitudinal inference and increasingly stringent EVLU criteria\. The dashed line denotes equal proportions of harmful and helpful changes \(50%\)\.b, Reliability–coverage trade\-off across EVLU criteria\. Stronger evidence requirements reduced the harmful fraction among retained accuracy\-changing revisions while progressively reducing longitudinal\-branch retention, defined as the proportion of all post\-initial predictions for which the longitudinal branch was retained\. ## Discussion In this study, we identify longitudinal belief updating as a distinct reliability challenge for clinical LLMs\. Longitudinal self\-context more often worsened than improved prediction accuracy when it altered subsequent estimates, a pattern that generalized across model families and replicated for a second clinical endpoint\. Controlled interventions revealed asymmetric responsiveness to worsening versus improving evidence and causal susceptibility to supplied prior beliefs despite unchanged current evidence\. Prompting reduced prior\-directed influence without restoring reliable updating, whereas evidence validation identified a smaller, more reliable subset of revisions\. Together, these findings show that evolving patient evidence and model\-generated prior assessments should not be treated as interchangeable forms of longitudinal context\. The causal influence of supplied prior assessments is particularly important for longitudinal clinical AI\. Previous work has shown that LLM performance can depend on the ordering and presentation of clinical information and that models can be sensitive to prior hypotheses and contextual biases[Hager et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib4);[Mahajan et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib6);[Sheppert et al\. \(2026\)](https://arxiv.org/html/2610.02684#bib.bib10)\. Our findings identify a related but distinct problem that arises when a model’s own preceding output becomes part of its subsequent input\. In natural longitudinal trajectories, an association between preceding and subsequent predictions cannot distinguish the influence of the prior assessment from that of concurrently evolving patient evidence\. The controlled prior\-belief intervention isolates these factors: with current clinical evidence held fixed, increasing the supplied preceding risk from 10% to 90% shifted the subsequent estimate by 26\.18 percentage points for mechanical ventilation and by 24\.48 percentage points for vasopressor initiation\. The close agreement across independently constructed respiratory and hemodynamic endpoints indicates that susceptibility to supplied prior belief extends across these two clinically distinct prediction tasks\. This behavior should not be interpreted as a human\-like cognitive anchoring mechanism\. Rather, it demonstrates causal input–output dependence in which model\-generated assessments can influence subsequent risk estimates despite unchanged current evidence\. If an inaccurate assessment is propagated as context, it may therefore influence later predictions and allow errors to persist across a longitudinal reasoning chain\. More broadly, the persistence of harmful longitudinal dependence across model families and scales suggests that increasing model size alone does not consistently attenuate longitudinal unreliability\. A second challenge concerns responses to the direction of changing evidence\. Under controlled respiratory interventions, models generally revised risk in the clinically appropriate direction and more strongly as evidence strength increased, indicating recognition of both deterioration and improvement\. However, worsening evidence produced larger revisions than matched improving evidence, with deterioration\-directed asymmetry persisting at moderate and strong strengths after headroom normalization and across preceding\-error and outcome strata\. This distinction matters because reliable longitudinal reasoning requires more than sensitivity to deterioration\. Clinical trajectories also involve stabilization, recovery, treatment response, and de\-escalation, when elevated risk assessments should be revised downward if supported by new evidence\. Dynamic clinical prediction similarly requires repeated updating as time\-varying physiological information becomes available[Lapp et al\. \(2023\)](https://arxiv.org/html/2610.02684#bib.bib11);[Bull et al\. \(2020\)](https://arxiv.org/html/2610.02684#bib.bib26);[Andrinopoulou et al\. \(2021\)](https://arxiv.org/html/2610.02684#bib.bib27)\. A model that responds more strongly to worsening than comparable improving evidence may therefore be slower to relinquish an elevated assessment as its supporting evidence weakens\. Persistence of deterioration\-directed asymmetry after headroom normalization and across prediction\-error and outcome strata argues against probability\-scale constraints, inaccurate preceding predictions, or outcome composition as simple explanations\. The prompting experiments further show that reducing attraction toward a prior assessment is not equivalent to improving longitudinal belief updating\. Both evidence\-first and anti\-anchoring instructions reduced the mean prior\-directed shift, but neither improved reliability; anti\-anchoring instead increased both the frequency of harmed snapshots and mean absolute error\. A longitudinal model must determine not simply whether to trust its previous assessment, but whether the resulting revision is justified by current evidence\. Global instructions to prioritize current evidence or distrust prior assessments provide no such case\-specific validation\. Longitudinal reliability therefore cannot be reduced to a generic instruction to “avoid anchoring,” consistent with evidence that prompt\-based self\-correction is often unreliable without informative external feedback[Kamoi et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib22)\. This distinction motivated our evidence\-validation analysis\. External or independently derived feedback has been explored to improve model correction[Pan et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib25);[Kamoi et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib22)\. Evidence\-Validated Longitudinal Update \(EVLU\) tested whether objective changes in patient evidence could identify more reliable context\-induced revisions by retaining longitudinal predictions only when their correction direction was concordant with changing respiratory evidence\. Increasing the required evidence score produced a reliability–coverage trade\-off\. With EVLU\-2, the harmful fraction among accuracy\-changing predictions fell from 60\.4% to 46\.9% and excess mean absolute error relative to independent inference approached zero, while only 5\.63% of post\-initial predictions retained the longitudinal branch\. Importantly, the greater reliability of EVLU\-2\-retained revisions was not explained by low retention alone\. Random gates retaining the same number of nontrivial longitudinal revisions preserved a higher harmful fraction and positive harmful\-update asymmetry, whereas EVLU\-2 shifted the balance toward more helpful than harmful changes\. EVLU\-2\-retained revisions were also more reliable than rejected revisions, indicating that evidence concordance identified more trustworthy longitudinal revisions beyond simply restricting their frequency\. This selectivity nevertheless represents an important limitation rather than a complete solution\. A stricter EVLU\-3 threshold produced numerically more favorable update\-quality measures but retained only 1\.68% of post\-initial predictions, without statistically distinguishable improvements over EVLU\-2\. Even EVLU\-2\-retained revisions did not improve mean absolute error over independent inference on average\. EVLU should therefore be viewed as a conservative proof of concept for evidence\-validated belief revision rather than a deployment\-ready strategy\. Future methods will need to preserve this selectivity while substantially increasing useful longitudinal coverage\. These findings have broader implications for clinical AI systems that operate repeatedly over time\. Snapshot\-level evaluation cannot reveal whether earlier model\-generated assessments improve, distort, or constrain subsequent reasoning\. Although longitudinal clinical AI increasingly represents extended patient histories and temporal relationships[Kruse et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib9);[Li et al\. \(2026\)](https://arxiv.org/html/2610.02684#bib.bib12), access to longitudinal information does not ensure reliable longitudinal reasoning\. Model\-generated history may provide continuity but must remain revisable in light of new patient evidence\. Evidence validation provides one possible design principle: longitudinal systems could test whether a context\-induced revision is supported by independently evolving clinical evidence before propagating it forward\. This selective use of context parallels approaches that trade coverage for reliability by deferring insufficiently trustworthy predictions[Dvijotham et al\. \(2023\)](https://arxiv.org/html/2610.02684#bib.bib24)\. Longitudinal evaluations should therefore assess not only discrimination and calibration, but also the direction, magnitude, evidence dependence, and consequences of belief revision over time[Hager et al\. \(2024\)](https://arxiv.org/html/2610.02684#bib.bib4);[Rao et al\. \(2026\)](https://arxiv.org/html/2610.02684#bib.bib8);[Kruse et al\. \(2025\)](https://arxiv.org/html/2610.02684#bib.bib9)\. Several limitations should be considered\. First, both endpoint\-specific cohorts were derived from MIMIC\-IV\. Although the natural longitudinal failure pattern and controlled prior\-belief susceptibility replicated across respiratory and hemodynamic deterioration cohorts, generalizability to other institutions, populations, clinical tasks, and timescales remains to be established\. Second, trajectories were constructed primarily from structured clinical variables; notes, imaging, treatment decisions, and other real\-world information could alter evidence integration and dependence on preceding assessments\. Third, the controlled respiratory perturbations were designed to isolate directional evidence updating and should not be interpreted as naturally occurring counterfactual trajectories\. Fourth, although harmful longitudinal updating was consistent across models, the mechanistic, prompting, and evidence\-validation experiments focused on the primary model and require replication across model families\. Fifth, absolute discrimination was modest\. Our analysis was designed to isolate within\-snapshot belief revision under matched inference conditions rather than optimize clinical risk prediction; whether these updating failures persist in clinically optimized or task\-adapted models remains to be established\. Sixth, EVLU relies on manually specified respiratory evidence rules and provides a conservative rather than comprehensive solution\. Although matched\-retention analyses showed that its reliability gains were not attributable solely to reduced longitudinal\-context use, more reliable operating points retained only a small fraction of longitudinal revisions\. EVLU therefore establishes evidence validation as an interpretable design principle rather than a clinically validated gating system\. Future work should evaluate evidence validation across independent datasets and endpoints, incorporate multimodal and unstructured evidence, and develop learned or task\-adaptive strategies that increase useful coverage without reintroducing unsupported prior dependence\. Prospective and clinician\-centered evaluation will ultimately be necessary before clinical deployment, consistent with evidence that real\-world clinical utility cannot be inferred from model\-level performance alone[Leibovitch et al\. \(2026\)](https://arxiv.org/html/2610.02684#bib.bib13);[Agweyu et al\. \(2026\)](https://arxiv.org/html/2610.02684#bib.bib14)\. In summary, longitudinal belief updating represents a distinct reliability challenge for clinical LLMs\. Supplied prior assessments can causally influence subsequent risk estimates despite unchanged current evidence, while evolving evidence produces asymmetric revision between worsening and improving states\. Prompting did not restore longitudinal reliability\. Evidence validation preferentially identified more reliable revisions beyond reduced longitudinal\-context retention alone, although at substantial cost to coverage\. Clinical LLMs intended for repeated use should therefore be evaluated not only on what they predict, but also on how, when, and on what evidence they revise preceding assessments\. ## Methods ### Data source and study cohort We used MIMIC\-IV version 3\.1[Johnson et al\. \(2023\)](https://arxiv.org/html/2610.02684#bib.bib1), a publicly available de\-identified electronic health record dataset containing hospital and intensive care unit \(ICU\) data\. We considered adult ICU stays from patients aged 18 years or older and required a minimum ICU length of stay of 30 hours to ensure sufficient longitudinal observation\. The study focused on evolving clinical deterioration during the early ICU course, with invasive mechanical ventilation as the primary endpoint and continuous vasopressor initiation as an independently constructed hemodynamic replication endpoint\. For the vasopressor replication analysis, the corresponding structured fields described hemodynamic assessment and 24\-hour vasopressor risk, while all other aspects of the independent and longitudinal inference protocol were unchanged\. The creation and sharing of MIMIC\-IV were approved by the Institutional Review Board of Beth Israel Deaconess Medical Center, with a waiver of informed consent\. The present study used only de\-identified data available through PhysioNet\. We constructed a matched cohort consisting of ICU stays that subsequently underwent invasive mechanical ventilation and control stays without qualifying ventilation events\. Invasive ventilation events were identified from structured ICU records using prespecified rules for invasive airway devices, ventilation modes, oxygen\-delivery fields, and procedure labels, while explicitly excluding non\-invasive respiratory\-support modalities\. For each ICU stay, the first qualifying invasive ventilation event was defined as the ventilation onset time\. ### Invasive ventilation outcome and matched cohort construction Ventilation\-positive ICU stays were required to have their first invasive ventilation event between 12 and 72 hours after ICU admission\. This interval ensured that sufficient clinical history was available before ventilation while restricting the analysis to early ICU deterioration\. Candidate positive stays were further required to contain at least two scheduled clinical snapshots occurring before ventilation onset\. Clinical snapshots were scheduled at 6, 12, 18, and 24 hours after ICU admission\. For ventilation\-positive stays, only snapshots occurring strictly before the first invasive ventilation event were retained\. At each snapshot, the prediction target was whether invasive mechanical ventilation would be initiated within the subsequent 24 hours\. We matched ventilation\-positive stays 1:1 to negative ICU stays without replacement\. Matching required the same sex and first ICU care unit, an age difference of no more than 10 years, and sufficient ICU duration for the negative stay to support the complete snapshot schedule of its matched positive case together with the subsequent 24\-hour prediction horizon\. Among 65,366 ICU stays screened, 2,025 met the initial positive eligibility criteria and 24,998 were eligible negative controls\. After requiring at least two pre\-ventilation snapshots, 2,023 positive stays remained\. We selected 1,000 matched pairs, yielding 2,000 unique ICU stays corresponding to 2,000 unique patients\. Seven positive candidates considered during matching could not be assigned an eligible control before the target cohort size was reached\. Among the final matched pairs, the mean absolute age difference was 0\.02 years and the maximum difference was 4 years\. ### Longitudinal clinical trajectory construction For each matched ICU stay, we constructed a longitudinal trajectory from structured EHR measurements available up to each scheduled snapshot\. The clinical state included vital signs and respiratory measurements, including oxygen saturation, respiratory rate, heart rate, systolic and diastolic blood pressure, temperature, fraction of inspired oxygen, and supplemental oxygen flow, together with laboratory measurements including arterial oxygen and carbon dioxide pressure, pH, lactate, white blood cell count, bicarbonate, and creatinine\. For each snapshot at timett, we represented two complementary views of the patient’s clinical state\. The*current state*summarized measurements available within the preceding 24 hours, whereas*new evidence*contained measurements and respiratory\-support events observed since the immediately preceding snapshot\. Numerical measurements were summarized using the most recent value together with the observed minimum, maximum, median, and measurement count within the corresponding interval\. The binary snapshot\-level outcome was defined as yt=𝕀\(t<Tvent≤t\+24h\),y\_\{t\}=\\mathbb\{I\}\\left\(t<T\_\{\\mathrm\{vent\}\}\\leq t\+24\\mathrm\{h\}\\right\), whereTventT\_\{\\mathrm\{vent\}\}denotes the first invasive ventilation time\. All snapshots from ventilation\-positive patients were verified to occur strictly before ventilation onset\. The resulting cohort contained 6,580 longitudinal snapshots, with 3,290 snapshots from ventilation\-positive patients and 3,290 from their matched controls\. ### Independent vasopressor cohort To evaluate generalization across clinical deterioration domains, we independently constructed a second endpoint\-specific cohort for continuous vasopressor initiation\. Vasopressor exposure was identified from MIMIC\-IVinputeventsusing continuous medication records for dopamine, epinephrine, norepinephrine, phenylephrine, and vasopressin\. Drug\-push administrations were excluded\. For each ICU stay, the first qualifying continuous vasopressor administration was defined as the vasopressor initiation time, and the prediction target at each snapshot was whether continuous vasopressor support would be initiated within the subsequent 24 hours\. Cohort construction paralleled the invasive mechanical ventilation analysis\. Vasopressor\-positive stays were required to have their first continuous vasopressor initiation between 12 and 72 hours after ICU admission and at least two scheduled snapshots strictly preceding vasopressor initiation\. Negative stays had no detected continuous vasopressor administration during the ICU stay\. Among 44,573 adult ICU stays satisfying the length\-of\-stay criterion, 2,352 met the positive endpoint criteria and 28,049 were eligible strict negative controls\. Positive stays were independently matched 1:1 without replacement to negative stays, requiring the same sex and first ICU care unit, an age difference of no more than 10 years, and sufficient follow\-up in the negative stay to cover the corresponding snapshot schedule and subsequent 24\-hour prediction horizon\. We randomly selected 1,000 eligible vasopressor\-positive stays and matched each 1:1 to an eligible negative stay without replacement, yielding 1,000 matched pairs and 2,000 unique ICU stays corresponding to 2,000 unique patients\. Clinical snapshots were scheduled at 6, 12, 18, and 24 hours after ICU admission, as in the primary analysis\. For the vasopressor endpoint, structured clinical evidence emphasized hemodynamic state and included heart rate, systolic and diastolic blood pressure, mean arterial pressure, lactate, urine output, creatinine, bicarbonate, and white blood cell count\. The independent and longitudinal evaluation conditions otherwise followed the same protocol as the invasive mechanical ventilation analysis, with the longitudinal condition additionally receiving the model’s structured assessment from the preceding snapshot\. ### Independent and longitudinal LLM evaluation We evaluated clinical belief updating under two matched inference conditions\. In the*independent*condition, the model assessed each clinical snapshot independently using only the patient information available up to the current time point\. The model therefore had no access to its own assessment from the preceding snapshot\. In the*longitudinal*condition, the model received the same current clinical information together with its structured assessment from the immediately preceding snapshot\. The prior assessment included the previous respiratory assessment, predicted probability of invasive ventilation within 24 hours, and evidence identified for and against respiratory deterioration\. At each subsequent snapshot, the model was instructed to either maintain or revise its previous assessment according to the newly available clinical evidence\. For the mechanical\-ventilation endpoint, the model produced a structured response containing a respiratory assessment, a predicted probability of invasive ventilation within the subsequent 24 hours, evidence supporting and arguing against deterioration, and aKEEPorREVISEdecision when prior context was available\. The vasopressor replication used the corresponding endpoint\-specific schema with a hemodynamic assessment, a predicted probability of continuous vasopressor initiation within the subsequent 24 hours, supporting and opposing hemodynamic evidence, and the sameKEEPorREVISEdecision structure\. We used Qwen3\-8B as the primary model and performed deterministic local inference with sampling disabled and visible chain\-of\-thought generation disabled\. For each snapshot after the first observation, we quantified the effect of prior model context as Δtcontext=Ptlong−Ptind,\\Delta\_\{t\}^\{\\mathrm\{context\}\}=P\_\{t\}^\{\\mathrm\{long\}\}\-P\_\{t\}^\{\\mathrm\{ind\}\}, wherePtlongP\_\{t\}^\{\\mathrm\{long\}\}andPtindP\_\{t\}^\{\\mathrm\{ind\}\}denote the longitudinal and independent ventilation\-risk estimates, respectively\. We additionally compared absolute prediction error, Brier score, and discrimination between the two conditions\. ### Cross\-model evaluation To assess whether harmful longitudinal dependence generalized across model families and scales, we repeated the independent and longitudinal evaluation on the same 2,000\-patient mechanical\-ventilation cohort using Qwen3\-32B, Llama\-3\.1\-8B\-Instruct, Mistral\-7B\-Instruct\-v0\.3, Mistral\-Small\-3\.1\-24B\-Instruct\-2503, MedGemma\-4B\-IT, MedGemma\-27B\-Text\-IT, and Gemma\-3\-12B\-IT, in addition to the primary Qwen3\-8B model\. All models received the same clinical snapshots, prediction target, and independent\-versus\-longitudinal prompt structure\. All models were evaluated locally with deterministic decoding using their model\-specific chat templates\. ### Controlled respiratory evidence interventions To distinguish systematic evidence\-responsive belief updating from changes arising from naturally evolving patient trajectories, we constructed a controlled counterfactual experiment\. For each eligible transition between consecutive longitudinal snapshots, we fixed both the patient’s preceding objective respiratory state and the model’s preceding longitudinal assessment, and varied only the newly presented respiratory evidence\. We generated six directional interventions defined by two evidence directions \(*worsening*and*improving*\) and three evidence strengths \(*subtle*,*moderate*, and*strong*\)\. Interventions were patient specific and were generated relative to the observed respiratory state at the preceding snapshot\. For worsening interventions, respiratory rate and supplemental oxygen requirements were increased while oxygen saturation was decreased; improving interventions applied the corresponding changes in the opposite direction\. The subtle, moderate, and strong interventions altered respiratory rate by 4, 8, and 14 breaths/min, oxygen saturation by 2, 4, and 7 percentage points, and supplemental oxygen flow by 1, 2, and 4 L/min, respectively, subject to predefined physiological bounds\. Intervention direction and magnitude were defined independently of the observed clinical outcome\. Two control conditions were additionally constructed\. In the*redundant*condition, the newly presented evidence explicitly restated the preceding respiratory measurements without changing their values\. In the*neutral*condition, the model was informed that no new respiratory measurements or directional evidence were available\. These controls were designed to determine whether belief revision reflected clinically meaningful evidence rather than generic sensitivity to the presence of additional prompt content\. Transitions were included in the controlled experiment when both respiratory rate and oxygen saturation were available at the preceding snapshot\. Of 4,580 real longitudinal transitions, 4,545 \(99\.2%\) satisfied these criteria\. Each transition was evaluated under all eight counterfactual conditions, producing 36,360 model responses in a fully paired design\. ### Controlled prior\-belief interventions To isolate the causal influence of prior model beliefs from changes in current patient evidence, we performed controlled prior\-belief interventions on all post\-initial snapshots\. For each snapshot, the current clinical evidence and corresponding user prompt were held identical across intervention conditions, while only the numerical risk estimate supplied in the previous model assessment was manipulated\. We evaluated five synthetic prior\-risk conditions: 10%, 30%, 50%, 70%, and 90%\. For the mechanical\-ventilation endpoint, the remaining fields of the previous assessment consisted of an empty respiratory assessment and empty lists of evidence for and against deterioration\. For the vasopressor endpoint, the corresponding hemodynamic assessment and evidence fields were likewise held empty and identical across conditions\. Thus, within each endpoint, the intervention varied only the numerical prior belief while preserving the current patient state and all other prompt content\. For the mechanical\-ventilation cohort, each of the 4,580 post\-initial snapshots was evaluated under all five prior\-risk conditions using the same model and inference configuration as in the primary longitudinal experiment, yielding 22,900 model responses\. Of these, 4,574 snapshots had valid predictions under all five intervention conditions and were included in complete\-case dose–response analyses\. We repeated the identical intervention protocol in the independently constructed vasopressor cohort\. Each of 4,444 post\-initial snapshots was evaluated under the same five prior\-risk conditions, yielding 22,220 model responses; 4,440 snapshots had valid predictions under all five conditions and were retained for complete\-case analyses\. For each endpoint, we quantified prior susceptibility as the mean change in the subsequent risk prediction associated with a 10\-percentage\-point increase in supplied prior risk\. We additionally measured the within\-snapshot difference between predictions under the 90% and 10% prior conditions and the proportion of snapshots for which updated risk was monotonically non\-decreasing across the five prior\-risk levels\. To evaluate the consequences of correct versus misleading prior beliefs, we classified the extreme prior conditions according to their alignment with the observed binary outcome\. For outcome\-positive snapshots, the 90% prior was treated as outcome\-aligned and the 10% prior as outcome\-misaligned; for outcome\-negative snapshots, the 10% prior was treated as outcome\-aligned and the 90% prior as outcome\-misaligned\. Absolute prediction error was compared between these paired conditions\. Because current clinical evidence was held fixed within each snapshot and only the supplied prior risk was experimentally manipulated, differences in subsequent predictions across intervention conditions isolate the effect of the supplied prior belief\. ### Prompt\-based mitigation To test whether instruction\-level interventions could reduce harmful dependence on previous model assessments, we evaluated two alternative longitudinal prompting strategies using Qwen3\-8B\. The*evidence\-first*strategy instructed the model to first assess the current clinical snapshot independently and form an initial ventilation\-risk estimate before reviewing the preceding model assessment as historical context\. The*anti\-anchoring*strategy explicitly instructed the model that the preceding assessment could be inaccurate, outdated, or overly confident and should not be treated as evidence about the current patient state\. Both prompts emphasized that the current clinical evidence should take precedence when it conflicted with the preceding assessment\. Each strategy was evaluated on all 4,580 post\-initial snapshots using the same current clinical information, preceding model assessments, output format, and deterministic inference configuration as the standard longitudinal condition\. The independent current\-snapshot predictions were unchanged and served as the common reference condition\. We compared each prompting strategy with the standard longitudinal prompt using the proportion of snapshots harmed by longitudinal context, the harmful fraction among accuracy\-changing predictions, normalized harmful\-update asymmetry, change in mean absolute prediction error relative to independent inference, and the magnitude of prior\-directed movement\. ### Evidence\-validated longitudinal updating To test whether harmful longitudinal dependence could be mitigated by requiring support from evolving patient evidence, we developed an Evidence\-Validated Longitudinal Update \(EVLU\) strategy\. EVLU is a rule\-based post hoc validation procedure and requires neither additional model training nor additional LLM inference\. For each post\-initial snapshottt, we defined the context\-induced longitudinal correction as Δtctx=Ptlong−Ptind,\\Delta\_\{t\}^\{\\mathrm\{ctx\}\}=P\_\{t\}^\{\\mathrm\{long\}\}\-P\_\{t\}^\{\\mathrm\{ind\}\},\(1\)wherePtindP\_\{t\}^\{\\mathrm\{ind\}\}is the ventilation\-risk estimate obtained from the current snapshot alone andPtlongP\_\{t\}^\{\\mathrm\{long\}\}is the estimate obtained when the previous model assessment is additionally provided\. We independently characterized the direction of change in structured respiratory evidence between consecutive snapshots\. Seven respiratory variables were considered when available: SpO2, FiO2, oxygen flow, respiratory rate, PaO2, PaCO2, and pH\. Each variable contributed a directional votevtj∈\{−1,0,\+1\}v\_\{tj\}\\in\\\{\-1,0,\+1\\\}, representing improvement, no meaningful change, or deterioration, respectively\. A vote was assigned only when the change exceeded a prespecified minimum threshold: 2 percentage points for SpO2, 5 percentage points for FiO2, 1 L/min for oxygen flow, 3 breaths/min for respiratory\-rate abnormality, 10 mmHg for PaO2, 5 mmHg for PaCO2, and 0\.03 for pH\. Decreases in SpO2, PaO2, and pH and increases in FiO2, oxygen flow, and PaCO2were treated as evidence of deterioration; respiratory rate was scored according to increasing deviation from the reference range of 12–20 breaths/min\. Changes in the opposite direction were treated as evidence of improvement\. Variables unavailable at either snapshot did not contribute a directional vote\. The net evidence score was Ct=∑jvtj,C\_\{t\}=\\sum\_\{j\}v\_\{tj\},\(2\)with positive values indicating net evidence of respiratory deterioration and negative values indicating net evidence of improvement\. For a concordance thresholdkk, a non\-zero longitudinal correction was retained only when the absolute net evidence score was at leastkkand its direction agreed with the direction of the context\-induced correction: wt\(k\)=𝕀\(\|Ct\|≥k∧sign\(Ct\)=sign\(Δtctx\)\)\.w\_\{t\}^\{\(k\)\}=\\mathbb\{I\}\\left\(\|C\_\{t\}\|\\geq k\\;\\land\\;\\operatorname\{sign\}\(C\_\{t\}\)=\\operatorname\{sign\}\(\\Delta\_\{t\}^\{\\mathrm\{ctx\}\}\)\\right\)\.\(3\)The resulting EVLU prediction was PtEVLU−k=Ptind\+wt\(k\)\(Ptlong−Ptind\)\.P\_\{t\}^\{\\mathrm\{EVLU\}\-k\}=P\_\{t\}^\{\\mathrm\{ind\}\}\+w\_\{t\}^\{\(k\)\}\\left\(P\_\{t\}^\{\\mathrm\{long\}\}\-P\_\{t\}^\{\\mathrm\{ind\}\}\\right\)\.\(4\)Thus, when a non\-zero longitudinal revision was supported by a sufficiently large net respiratory evidence score in the same direction, EVLU retained the longitudinal prediction; otherwise, it reverted to the current\-snapshot\-only prediction\. We evaluated concordance thresholdsk=1,2,3k=1,2,3to characterize the trade\-off between retaining longitudinal information and selectively accepting more strongly corroborated revisions\. These thresholds were evaluated as a sensitivity analysis rather than selected by optimizing outcome performance\. No outcome labels were used to construct the evidence score or determine whether an individual longitudinal revision was retained\. We compared EVLU with unrestricted longitudinal inference and independent current\-snapshot inference\. Primary mitigation outcomes were the fraction of retained changed predictions that increased absolute prediction error, normalized harmful\-update asymmetry, change in mean absolute error relative to independent inference, and longitudinal\-update retention, defined as the proportion of all post\-initial predictions for which the longitudinal branch was retained\. Confidence intervals for paired policy comparisons were estimated using stay\-cluster bootstrap resampling with 5,000 replicates\. ### Evaluation metrics We evaluated model behavior from both predictive\-performance and belief\-updating perspectives\. For the natural longitudinal evaluation, predictive performance was assessed using the area under the receiver operating characteristic curve \(AUROC\), Brier score, and mean absolute error \(MAE\) between the predicted probability of invasive ventilation and the binary 24\-hour outcome\. To quantify the effect of prior model context, we computed the paired prediction difference at each snapshot after the first observation as Δtcontext=Ptlong−Ptind,\\Delta\_\{t\}^\{\\mathrm\{context\}\}=P\_\{t\}^\{\\mathrm\{long\}\}\-P\_\{t\}^\{\\mathrm\{ind\}\}, wherePtlongP\_\{t\}^\{\\mathrm\{long\}\}andPtindP\_\{t\}^\{\\mathrm\{ind\}\}denote the longitudinal and independent ventilation\-risk estimates, respectively\. We additionally report the absolute condition difference, \|Ptlong−Ptind\|,\\left\|P\_\{t\}^\{\\mathrm\{long\}\}\-P\_\{t\}^\{\\mathrm\{ind\}\}\\right\|, to quantify the magnitude of belief change induced by access to the prior assessment\. To determine whether prior context improved or worsened prediction accuracy, we calculated the change in absolute prediction error, ΔEt=\|Ptlong−yt\|−\|Ptind−yt\|,\\Delta E\_\{t\}=\\left\|P\_\{t\}^\{\\mathrm\{long\}\}\-y\_\{t\}\\right\|\-\\left\|P\_\{t\}^\{\\mathrm\{ind\}\}\-y\_\{t\}\\right\|, whereyt∈\{0,1\}y\_\{t\}\\in\\\{0,1\\\}is the snapshot\-level ventilation outcome\. A negative value indicates that longitudinal context improved prediction accuracy, whereas a positive value indicates that it increased prediction error\. We accordingly categorized snapshots as*helped*,*hurt*, or*no effect*\. Among snapshots with a non\-zero change in absolute prediction error, the harmful fraction was defined as Fharm=NhurtNhurt\+Nhelped,F\_\{\\mathrm\{harm\}\}=\\frac\{N\_\{\\mathrm\{hurt\}\}\}\{N\_\{\\mathrm\{hurt\}\}\+N\_\{\\mathrm\{helped\}\}\},and normalized harmful\-update asymmetry was defined as Aharm=Nhurt−NhelpedNhurt\+Nhelped\.A\_\{\\mathrm\{harm\}\}=\\frac\{N\_\{\\mathrm\{hurt\}\}\-N\_\{\\mathrm\{helped\}\}\}\{N\_\{\\mathrm\{hurt\}\}\+N\_\{\\mathrm\{helped\}\}\}\.Thus,Aharm\>0A\_\{\\mathrm\{harm\}\}\>0indicates that harmful effects were more frequent than helpful effects among accuracy\-changing predictions\. We quantified prior\-belief attraction using a prior\-directed shift measure, which was also used in the prompting analyses\. This measure was defined as PriorPullt=\|Ptind−Pt−1long\|−\|Ptlong−Pt−1long\|\.\\mathrm\{PriorPull\}\_\{t\}=\\left\|P\_\{t\}^\{\\mathrm\{ind\}\}\-P\_\{t\-1\}^\{\\mathrm\{long\}\}\\right\|\-\\left\|P\_\{t\}^\{\\mathrm\{long\}\}\-P\_\{t\-1\}^\{\\mathrm\{long\}\}\\right\|\. Positive values indicate that the longitudinal prediction remained closer to the model’s preceding belief than the independent prediction based on the current clinical state alone\. For the controlled counterfactual experiment, belief revision was quantified as ΔP=Pupdated−Pprior,\\Delta P=P\_\{\\mathrm\{updated\}\}\-P\_\{\\mathrm\{prior\}\}, wherePpriorP\_\{\\mathrm\{prior\}\}is the model’s risk estimate before the controlled evidence intervention andPupdatedP\_\{\\mathrm\{updated\}\}is the corresponding estimate after incorporating the intervention\. For worsening evidence, positiveΔP\\Delta Prepresents directionally appropriate updating; for improving evidence, negativeΔP\\Delta Prepresents directionally appropriate updating\. We report the mean and median change in risk, mean absolute change, and the proportions of positive, negative, and unchanged revisions\. To characterize evidence\-strength sensitivity, we evaluated dose\-response behavior across subtle, moderate, and strong interventions\. A transition was considered monotonic when the magnitude of belief revision was non\-decreasing across increasing evidence strengths\. Directional asymmetry was quantified on the raw probability scale as Araw=ΔPworsening\+ΔPimproving,A\_\{\\mathrm\{raw\}\}=\\Delta P\_\{\\mathrm\{worsening\}\}\+\\Delta P\_\{\\mathrm\{improving\}\}, becauseΔPimproving\\Delta P\_\{\\mathrm\{improving\}\}is expected to be negative\. Thus,Araw=0A\_\{\\mathrm\{raw\}\}=0represents equal\-magnitude updating in opposite directions, whereasAraw\>0A\_\{\\mathrm\{raw\}\}\>0indicates stronger deterioration\-directed updating\. Because probability estimates are bounded between 0 and 100, the available upward and downward revision ranges depend on the prior risk\. We therefore additionally calculated headroom\-normalized directional responses: Rworsening=ΔPworsening100−Pprior,R\_\{\\mathrm\{worsening\}\}=\\frac\{\\Delta P\_\{\\mathrm\{worsening\}\}\}\{100\-P\_\{\\mathrm\{prior\}\}\}, and Rimproving=−ΔPimprovingPprior\.R\_\{\\mathrm\{improving\}\}=\\frac\{\-\\Delta P\_\{\\mathrm\{improving\}\}\}\{P\_\{\\mathrm\{prior\}\}\}\. The normalized asymmetry score was defined as Anorm=Rworsening−Rimproving\.A\_\{\\mathrm\{norm\}\}=R\_\{\\mathrm\{worsening\}\}\-R\_\{\\mathrm\{improving\}\}\. PositiveAnormA\_\{\\mathrm\{norm\}\}indicates stronger deterioration\-directed belief updating after accounting for the unequal upward and downward probability headroom\. ### Statistical analysis All primary comparisons were paired at the clinical\-snapshot or transition level, as appropriate\. Because multiple observations could be contributed by the same ICU stay, uncertainty was quantified using cluster bootstrap resampling at the ICU\-stay level to preserve within\-stay dependence\. Unless otherwise specified, 95% confidence intervals were estimated using 10,000 ICU\-stay\-level bootstrap replicates\. For the natural longitudinal evaluation, independent and longitudinal predictions were compared at matched clinical snapshots\. Predictive performance was summarized using AUROC, Brier score, and mean absolute error \(MAE\)\. For post\-initial snapshots, we additionally summarized the paired difference between longitudinal and independent risk estimates and classified context\-induced changes as harmful, helpful, or having no effect according to their effect on absolute prediction error\. Cross\-model uncertainty for harmful\-update asymmetry was estimated by ICU\-stay\-level bootstrap resampling\. For the controlled respiratory evidence interventions, all worsening and improving conditions were paired within the same longitudinal transition\. Directional asymmetry was evaluated on both the raw probability scale and after normalization by the available upward or downward probability headroom, as defined above\. We additionally examined headroom\-normalized asymmetry across strata of preceding predicted risk, preceding prediction error, and clinical outcome\. For the controlled prior\-belief interventions, all prior\-risk conditions were paired within the same clinical snapshot while current clinical evidence was held fixed\. Prior susceptibility was quantified from the within\-snapshot dose–response relationship across the five supplied prior\-risk levels\. Uncertainty for the mean effect of a 10\-percentage\-point increase in supplied prior risk, the 90%\-versus\-10% contrast, monotonicity, and the comparison between outcome\-aligned and outcome\-misaligned priors was estimated by ICU\-stay\-level bootstrap resampling\. For the prompt\-based mitigation analyses, each alternative longitudinal prompt was compared with the standard longitudinal prompt using the same post\-initial snapshots and the same independent predictions as the common reference\. Differences in harmful\-update measures, mean absolute error, and prior\-directed shift were evaluated using paired ICU\-stay\-level bootstrap resampling with 5,000 replicates\. For EVLU, policy\-level outcomes were compared with unrestricted longitudinal inference and independent current\-snapshot inference using paired ICU\-stay\-level bootstrap resampling with 5,000 replicates\. To determine whether the greater reliability of EVLU\-2\-retained revisions could be explained solely by low longitudinal\-branch retention, we performed a matched\-random retention analysis among the 3,503 nontrivial longitudinal revisions\. EVLU\-2 retained 258 such revisions\. We therefore generated 10,000 random assignments, each retaining exactly 258 of the 3,503 nontrivial revisions, and recomputed the harmful fraction, normalized harmful\-update asymmetry, and change in mean absolute error for each assignment\. The resulting randomization distributions were summarized using the 2\.5th and 97\.5th percentiles as 95% randomization intervals\. The one\-sided empirical randomizationPPvalue was calculated as\(1\+b\)/\(B\+1\)\(1\+b\)/\(B\+1\), whereB=10,000B=10\{,\}000andbbwas the number of random assignments yielding a harmful fraction at least as low as that observed under EVLU\-2\. We additionally compared EVLU\-2\-retained and rejected nontrivial revisions using ICU\-stay\-level cluster bootstrap resampling, with 10,000 replicates, for harmful fraction, normalized harmful\-update asymmetry, and mean change in absolute prediction error\. Primary analyses emphasized paired effect estimates with confidence intervals\. No adjustment for multiple comparisons was applied to exploratory subgroup or sensitivity analyses, which were interpreted descriptively rather than as independent confirmatory hypothesis tests\. Analyses were performed using Python\. ## Data Availability The clinical data used in this study were obtained from MIMIC\-IV, a publicly available de\-identified electronic health record database\. Access to MIMIC\-IV is available through PhysioNet to credentialed users who complete the required training and data\-use agreement\. The derived cohorts used in this study can be reconstructed from MIMIC\-IV using the cohort\-construction procedures described in the Methods and accompanying code\. ## Code Availability Code supporting this study, including scripts for cohort construction, longitudinal model evaluation, controlled interventions, and statistical analysis, is available to editors and reviewers through a private Zenodo reviewer\-access link\. The repository contains the scripts required to reproduce the analyses reported in this study from credentialed access to MIMIC\-IV and will be made publicly available upon publication\. ## Acknowledgements None\. ## Funding This work was supported by the National Center for Complementary and Integrative Health, United States \[grant numbers R01AT009457, U01AT012871\]; the National Institute on Aging, United States \[grant number R01AG078154\]; the National Cancer Institute, United States \[grant number R01CA287413\]; the National Institute of Diabetes and Digestive and Kidney Diseases, United States \[grant number R01DK115629\]; the National Institute on Minority Health and Health Disparities, United States \[grant number R21MD019134\]; and the Food and Drug Administration, United States \[grant number U01FD008720\]\. The funders had no role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript\. ## Author Contributions M\.Z\. conceived the study, developed the methodology, implemented the computational pipeline, performed the experiments and statistical analyses, interpreted the results, prepared the figures, and drafted the manuscript\. R\.Z\. contributed to study conception and design, supervised the work, provided resources and funding, contributed to interpretation of the results, and reviewed and edited the manuscript\. Both authors reviewed and approved the final manuscript\. ## Competing Interests The authors declare no competing interests\. ## References - A\. Agweyu, P\. Mwaniki, V\. Menon, R\. Korom, L\. Isaaka, C\. Wanyama, J\. Gill, S\. Kiptinness, N\. Adan, M\. Emmanuel\-Fabula, R\. D\. Riley, L\. Archer, A\. K\. Denniston, X\. Liu, and B\. A\. MateenGenerative ai\-enabled clinical decision support system in primary care: a pragmatic, cluster\-randomized trial\.Nature Medicine32,pp\. 3032–3039\.External Links:[Document](https://dx.doi.org/10.1038/s41591-026-04503-6)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p12.1)\. - Andrinopoulouet al\.\(2021\)E\. Andrinopoulou, M\. O\. Harhay, S\. J\. Ratcliffe, and D\. RizopoulosReflection on modern methods: dynamic prediction using joint models of longitudinal and time\-to\-event data\.International Journal of Epidemiology50\(5\),pp\. 1731–1743\.External Links:[Document](https://dx.doi.org/10.1093/ije/dyab047)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p5.1)\. - Bediet al\.\(2025\)S\. Bedi, Y\. Liu, L\. Orr\-Ewing, D\. Dash, S\. Koyejo, A\. Callahan, J\. A\. Fries, M\. Wornow, A\. Swaminathan, L\. S\. Lehmann, H\. J\. Hong, M\. Kashyap, A\. R\. Chaurasia, N\. R\. Shah, K\. Singh, T\. Tazbaz, A\. Milstein, M\. A\. Pfeffer, and N\. H\. ShahTesting and evaluation of health care applications of large language models: a systematic review\.JAMA333\(4\),pp\. 319–328\.External Links:[Document](https://dx.doi.org/10.1001/jama.2024.21700)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p1.1)\. - Bullet al\.\(2020\)L\. M\. Bull, M\. Lunt, G\. P\. Martin, K\. Hyrich, and J\. C\. SergeantHarnessing repeated measurements of predictor variables for clinical risk prediction: a review of existing methods\.Diagnostic and Prognostic Research4,pp\. 9\.External Links:[Document](https://dx.doi.org/10.1186/s41512-020-00078-z)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p5.1)\. - Cuiet al\.\(2025\)H\. Cui, A\. Unell, B\. Chen, J\. A\. Fries, E\. Alsentzer, S\. Koyejo,et al\.TIMER: temporal instruction modeling and evaluation for longitudinal clinical records\.npj Digital Medicine8,pp\. 577\.External Links:[Document](https://dx.doi.org/10.1038/s41746-025-01965-9)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p2.1)\. - Dvijothamet al\.\(2023\)K\. Dvijotham, J\. Winkens, M\. Barsbey, S\. Ghaisas, R\. Stanforth, N\. Pawlowski,et al\.Enhancing the reliability and accuracy of ai\-enabled diagnosis via complementarity\-driven deferral to clinicians\.Nature Medicine\.External Links:[Document](https://dx.doi.org/10.1038/s41591-023-02437-x)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p11.1)\. - Fleminget al\.\(2024\)S\. L\. Fleming, A\. Lozano, W\. J\. Haberkorn, J\. A\. Jindal, E\. Reis, R\. Thapa, K\. E\. Morse, E\. P\. Brunskill, J\. A\. Fries, and N\. H\. ShahMedAlign: a clinician\-generated dataset for instruction following with electronic medical records\.Proceedings of the AAAI Conference on Artificial Intelligence38\(20\),pp\. 22021–22030\.External Links:[Document](https://dx.doi.org/10.1609/aaai.v38i20.30205)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p2.1)\. - Hageret al\.\(2024\)P\. Hager, F\. Jungmann, R\. Holland, K\. Bhagat, I\. Hubrecht, M\. Knauer, J\. Vielhauer, M\. Makowski, R\. Braren, G\. Kaissis, and D\. RueckertEvaluation and mitigation of the limitations of large language models in clinical decision\-making\.Nature Medicine30\(9\),pp\. 2613–2622\.External Links:[Document](https://dx.doi.org/10.1038/s41591-024-03097-1)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p2.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p11.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p2.1)\. - Johnsonet al\.\(2023\)A\. E\. Johnson, L\. Bulgarelli, L\. Shen, A\. Gayles, A\. Shammout, S\. Horng, T\. J\. Pollard, S\. Hao, B\. Moody, B\. Gow,et al\.MIMIC\-iv, a freely accessible electronic health record dataset\.Scientific Data10\(1\),pp\. 1\.External Links:[Document](https://dx.doi.org/10.1038/s41597-022-01899-x)Cited by:[Construction of a matched longitudinal clinical cohort](https://arxiv.org/html/2610.02684#Sx2.SSx1.p1.1),[Data source and study cohort](https://arxiv.org/html/2610.02684#Sx4.SSx1.p1.1)\. - Johriet al\.\(2025\)S\. Johri, J\. Jeong, B\. A\. Tran, D\. I\. Schlessinger, S\. Wongvibulsin, L\. A\. Barnes, H\. Zhou, Z\. R\. Cai, E\. M\. Van Allen, D\. Kim, R\. Daneshjou, and P\. RajpurkarAn evaluation framework for clinical use of large language models in patient interaction tasks\.Nature Medicine31,pp\. 77–86\.External Links:[Document](https://dx.doi.org/10.1038/s41591-024-03328-5)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p2.1)\. - Kamoiet al\.\(2024\)R\. Kamoi, Y\. Zhang, N\. Zhang, J\. Han, and R\. ZhangWhen can LLMs actually correct their own mistakes? a critical survey of self\-correction of LLMs\.Transactions of the Association for Computational Linguistics12,pp\. 1417–1440\.External Links:[Document](https://dx.doi.org/10.1162/tacl%5Fa%5F00713)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p6.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p7.1)\. - Kruseet al\.\(2025\)M\. Kruse, S\. Hu, N\. Derby, Y\. Wu, S\. Stonbraker, B\. Yao, D\. Wang, E\. M\. Goldberg, and Y\. GaoLarge language models with temporal reasoning for longitudinal clinical summarization and prediction\.Findings of the Association for Computational Linguistics: EMNLP 2025,pp\. 20715–20735\.External Links:[Document](https://dx.doi.org/10.18653/v1/2025.findings-emnlp.1128)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p2.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p10.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p11.1)\. - Kwanet al\.\(2024\)W\. Kwan, X\. Zeng, Y\. Jiang, Y\. Wang, L\. Li, L\. Shang, X\. Jiang, Q\. Liu, and K\. WongMT\-eval: a multi\-turn capabilities evaluation benchmark for large language models\.Proceedings of the 2024 Conference on Empirical Methods in Natural Language Processing,pp\. 20153–20177\.External Links:[Document](https://dx.doi.org/10.18653/v1/2024.emnlp-main.1124)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p3.1)\. - Lappet al\.\(2023\)L\. Lapp, M\. Roper, K\. Kavanagh, M\. Bouamrane, and S\. SchraagDynamic prediction of patient outcomes in the intensive care unit: a scoping review of the state\-of\-the\-art\.Journal of Intensive Care Medicine38\(7\),pp\. 575–591\.External Links:[Document](https://dx.doi.org/10.1177/08850666231166349)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p5.1)\. - Leibovitchet al\.\(2026\)L\. Leibovitch, A\. Ahituv, A\. Gorenshtein, D\. Aran, M\. Sorka, K\. Miron,et al\.Prospective evaluation of a large language model clinical decision support system in the emergency department\.Nature Medicine\.External Links:[Document](https://dx.doi.org/10.1038/s41591-026-04601-5)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p12.1)\. - Liet al\.\(2026\)D\. Li, J\. Liang, W\. Li, X\. Wang, L\. Cao, and K\. YuCliCARE: grounding large language models in clinical guidelines for decision support over longitudinal cancer electronic health records\.Proceedings of the AAAI Conference on Artificial Intelligence40\(37\),pp\. 31554–31562\.External Links:[Document](https://dx.doi.org/10.1609/aaai.v40i37.40421)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p10.1)\. - Mahajanet al\.\(2025\)A\. Mahajan, Z\. Obermeyer, R\. Daneshjou, J\. Lester, and D\. PowellCognitive bias in clinical large language models\.npj Digital Medicine8,pp\. 428\.External Links:[Document](https://dx.doi.org/10.1038/s41746-025-01790-0)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p3.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p2.1)\. - Panet al\.\(2024\)L\. Pan, M\. Saxon, W\. Xu, D\. Nathani, X\. Wang, and W\. Y\. WangAutomatically correcting large language models: surveying the landscape of diverse automated correction strategies\.Transactions of the Association for Computational Linguistics12,pp\. 484–506\.External Links:[Document](https://dx.doi.org/10.1162/tacl%5Fa%5F00660)Cited by:[Discussion](https://arxiv.org/html/2610.02684#Sx3.p7.1)\. - Raoet al\.\(2026\)A\. S\. Rao, K\. P\. Esmail, R\. S\. Lee, S\. Jiang, B\. Arraiza Carlo, J\. Gill, P\. Khanna, E\. Kalmowitz, B\. Montagnese, K\. Heydari, Q\. Jiao, E\. Bott, D\. Nguyen, G\. Wang, M\. Hood, A\. B\. Landman, and M\. D\. SucciLarge language model performance and clinical reasoning tasks\.JAMA Network Open9\(4\),pp\. e264003\.External Links:[Document](https://dx.doi.org/10.1001/jamanetworkopen.2026.4003)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p2.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p11.1)\. - Sharmaet al\.\(2023\)M\. Sharma, M\. Tong, T\. Korbak, D\. Duvenaud, A\. Askell, S\. R\. Bowman, N\. Cheng, E\. Durmus, Z\. Hatfield\-Dodds, S\. R\. Johnston, S\. Kravec, T\. Maxwell, S\. McCandlish, K\. Ndousse, O\. Rausch, N\. Schiefer, D\. Yan, M\. Zhang, and E\. PerezTowards understanding sycophancy in language models\.arXiv preprint arXiv:2310\.13548\.External Links:[Document](https://dx.doi.org/10.48550/arXiv.2310.13548)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p3.1)\. - Sheppertet al\.\(2026\)A\. Sheppert, C\. Shen, E\. Geissal, C\. Riley, and S\. RileyLarge language models exhibit greater diagnostic anchoring than physicians in a forced\-choice vignette study\.International Journal of Medical Informatics219,pp\. 106550\.External Links:[Document](https://dx.doi.org/10.1016/j.ijmedinf.2026.106550)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p3.1),[Discussion](https://arxiv.org/html/2610.02684#Sx3.p2.1)\. - Singhalet al\.\(2023\)K\. Singhal, S\. Azizi, T\. Tu, S\. S\. Mahdavi, J\. Wei, H\. W\. Chung, N\. Scales, A\. Tanwani, H\. Cole\-Lewis, S\. Pfohl, P\. Payne, M\. Seneviratne, P\. Gamble, C\. Kelly, A\. Babiker, N\. Schärli, A\. Chowdhery, P\. Mansfield, D\. Demner\-Fushman, B\. Agüera y Arcas, D\. Webster, G\. S\. Corrado, Y\. Matias, K\. Chou, J\. Gottweis, N\. Tomasev, Y\. Liu, A\. Rajkomar, J\. Barral, C\. Semturs, A\. Karthikesalingam, and V\. NatarajanLarge language models encode clinical knowledge\.Nature620\(7972\),pp\. 172–180\.External Links:[Document](https://dx.doi.org/10.1038/s41586-023-06291-2)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p1.1)\. - Singhalet al\.\(2025\)K\. Singhal, T\. Tu, J\. Gottweis, R\. Sayres, E\. Wulczyn, M\. Amin, L\. Hou, K\. Clark, S\. R\. Pfohl, H\. Cole\-Lewis, D\. Neal, Q\. M\. Rashid, M\. Schaekermann, A\. Wang, D\. Dash, J\. H\. Chen, N\. H\. Shah, S\. Lachgar, P\. A\. Mansfield, S\. Prakash, B\. Green, E\. Dominowska, B\. Agüera y Arcas, N\. Tomašev, Y\. Liu, R\. Wong, C\. Semturs, S\. S\. Mahdavi, J\. K\. Barral, D\. R\. Webster, G\. S\. Corrado, Y\. Matias, S\. Azizi, A\. Karthikesalingam, and V\. NatarajanToward expert\-level medical question answering with large language models\.Nature Medicine31\(3\),pp\. 943–950\.External Links:[Document](https://dx.doi.org/10.1038/s41591-024-03423-7)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p1.1)\. - Tanet al\.\(2024\)H\. Tan, F\. Sun, W\. Yang, Y\. Wang, Q\. Cao, and X\. ChengBlinded by generated contexts: how language models merge generated and retrieved contexts when knowledge conflicts?\.Proceedings of the 62nd Annual Meeting of the Association for Computational Linguistics,pp\. 6207–6227\.External Links:[Document](https://dx.doi.org/10.18653/v1/2024.acl-long.337)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p3.1)\. - Thirunavukarasuet al\.\(2023\)A\. J\. Thirunavukarasu, D\. S\. J\. Ting, K\. Elangovan, L\. Gutierrez, T\. F\. Tan,et al\.Large language models in medicine\.Nature Medicine29,pp\. 1930–1940\.External Links:[Document](https://dx.doi.org/10.1038/s41591-023-02448-8)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p1.1)\. - Van Veenet al\.\(2024\)D\. Van Veen, C\. Van Uden, L\. Blankemeier, J\. Delbrouck, A\. Aali, C\. Bluethgen, A\. Pareek, M\. Polacin, E\. P\. Reis,et al\.Adapted large language models can outperform medical experts in clinical text summarization\.Nature Medicine30,pp\. 1134–1142\.External Links:[Document](https://dx.doi.org/10.1038/s41591-024-02855-5)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p1.1)\. - Wilieet al\.\(2024\)B\. Wilie, S\. Cahyawijaya, E\. Ishii, J\. He, and P\. FungBelief revision: the adaptability of large language models reasoning\.Proceedings of the 2024 Conference on Empirical Methods in Natural Language Processing,pp\. 10480–10496\.External Links:[Document](https://dx.doi.org/10.18653/v1/2024.emnlp-main.586)Cited by:[Introduction](https://arxiv.org/html/2610.02684#Sx1.p3.1)\.
相似文章
大型语言模型在医学推理中表现出元认知敏感性
一项对照研究评估了大型语言模型在医学推理中的元认知敏感性,发现部分但存在缺陷的置信度校准,其随证据强度和冲突情境而变化。
临床人员对语言模型的使用方式与模型的评估方式存在显著差异
该研究分析了6,342名临床人员在八个月内向机构LLM助手发送的127,833条查询,发现临床医生的实际使用方式与现有模型评估基准所衡量的内容存在显著差异,凸显了基准测试与真实部署之间的脱节。
偶然信息污染患者记录并干扰大型语言模型的临床推理
该研究发现,大型语言模型在临床文档和推理任务中容易受到无关信息(如寒暄对话、背景语音)的污染,提出临床推理与分心的双编码假设,并建议在临床部署前评估模型对无关信息的抵抗力。
在标准化病例中评估大语言模型在动态临床决策中的表现
研究人员提出了MedSP1000,这是一个包含1638个病例的交互式基准,源自标准化患者场景,用于评估大语言模型作为动态临床代理在多轮问诊中的表现。结果显示,即使是最佳模型(GPT-5.5)也仅完成了60.4%的专家评分项,表明当前的大语言模型在临床实践中尚不够可靠。
大型语言模型与中医医生在中医领域中的真实世界临床病例评估
该研究使用真实世界临床病例评估了16个大型语言模型与60位执业中医医生的表现,发现LLMs在某些领域获得更高的专家分数,但存在差异和安全问题。它强调了LLMs在中医决策支持中的潜力和局限性。