Abstract: Distribution operators need visibility of behind-the-meter photovoltaic (PV) generation, yet most residential customers are observed only through net smart meters. Deep-learning-based PV disaggregation can restore this visibility, but its operational value depends on whether the model serves known customers, new customers, future periods, or new regions. We quantify this dependence using four deployment regimes that separate household transfer from temporal extrapolation, applied to Ausgrid smart-meter data with cross-dataset adaptation to the Pecan Street data. Using a fixed training protocol, we benchmark representative deep sequence architectures for PV disaggregation under regime-matched evaluation. At a fixed 48-hour context length, daylight mean absolute error (MAE) of the best model rises from 0.104~kW on seen households in the future test period to 0.185~kW on unseen households over the same period, and under a fixed training contract the deployment regime explains far more of the error variation than model choice. Under target-domain normalization, fine-tuning on five target-region households reduces source-model transfer error by 28\%--36\%. Long input windows help known-customer extrapolation, while their new-customer benefits vary by model. These findings suggest regime-matched error budgets, limited target supervision for model adaptation in new regions, and use-case-dependent context selection for energy data analytics.
查看缓存全文
缓存时间: 2026/10/12 06:39
# Behind-the-Meter Photovoltaic Visibility from Net Smart Meters: Deployment Regimes and Operational Insights
Source: [https://arxiv.org/html/2610.12527](https://arxiv.org/html/2610.12527)
## Behind\-the\-Meter Photovoltaic Visibility from Net Smart Meters: Deployment Regimes and Operational InsightsThanks:\*Corresponding author: Hao Wang\.Thanks:This work was supported in part by the Australian Research Council \(ARC\) Discovery Early Career Researcher Award \(DECRA\) under Grant DE230100046\.
Jack Zheng1, Hao Wang1,2\*Affiliation:1Department of Data Science and AI, Faculty of IT, Monash University, Australia 2Monash Energy Institute, Monash University, Australia \{jack\.zheng, hao\.wang2\}@monash\.eduAffiliation:
###### Abstract
Distribution operators need visibility of behind\-the\-meter photovoltaic \(PV\) generation, yet most residential customers are observed only through net smart meters\. Deep\-learning\-based PV disaggregation can restore this visibility, but its operational value depends on whether the model serves known customers, new customers, future periods, or new regions\. We quantify this dependence using four deployment regimes that separate household transfer from temporal extrapolation, applied to Ausgrid smart\-meter data with cross\-dataset adaptation to the Pecan Street data\. Using a fixed training protocol, we benchmark representative deep sequence architectures for PV disaggregation under regime\-matched evaluation\. At a fixed 48\-hour context length, daylight mean absolute error \(MAE\) of the best model rises from 0\.104 kW on seen households in the future test period to 0\.185 kW on unseen households over the same period, and under a fixed training contract the deployment regime explains far more of the error variation than model choice\. Under target\-domain normalization, fine\-tuning on five target\-region households reduces source\-model transfer error by 28%–36%\. Long input windows help known\-customer extrapolation, while their new\-customer benefits vary by model\. These findings suggest regime\-matched error budgets, limited target supervision for model adaptation in new regions, and use\-case\-dependent context selection for energy data analytics\.
###### Index Terms:
Behind\-the\-meter photovoltaic, smart meter, distribution grid visibility, energy data analytics, deployment regimes, transfer learning\.
## IIntroduction
Energy Internet operation depends on digital visibility of distributed energy resources for trustworthy coordination\[[1](https://arxiv.org/html/2610.12527#bib.bib23)\], but residential photovoltaic \(PV\) generation is often hidden behind the customer meter\. Fig\.[1](https://arxiv.org/html/2610.12527#S1.F1)illustrates the visibility problem considered in this paper\. Most residential customers have a single net meter that reports the difference between consumption and generation rather than the two quantities separately\. Recovering the underlying PV generation profile supports distribution planning, load forecasting, demand\-response baseline construction, and monitoring of behind\-the\-meter resources as distributed PV penetration grows\[[2](https://arxiv.org/html/2610.12527#bib.bib1)\]\.
Fig\. 1:Behind\-the\-meter PV disaggregation problem\. The smart meter observes only net load, while PV generation is estimated from net load and solar\-weather features\.The disaggregation problem is underdetermined: a single net\-load value is the difference of two unobserved non\-negative quantities, and there are infinitely many consumption\-generation pairs consistent with any given net measurement\. Practical visibility therefore depends on learned structure, specifically the diurnal and weather\-driven shape of PV generation and the comparatively irregular shape of household consumption\. This structure is only partially shared across households: PV orientation, capacity, shading, appliance composition, and occupancy can all produce household\-specific signatures\. Reliance on these household\-specific cues can limit transfer to newly connected or newly instrumented customers\.
Existing studies report increasingly strong performance from deep sequence models, graph architectures, and generative approaches\[[3](https://arxiv.org/html/2610.12527#bib.bib3),[4](https://arxiv.org/html/2610.12527#bib.bib6),[5](https://arxiv.org/html/2610.12527#bib.bib7),[6](https://arxiv.org/html/2610.12527#bib.bib10),[7](https://arxiv.org/html/2610.12527#bib.bib11),[8](https://arxiv.org/html/2610.12527#bib.bib12),[9](https://arxiv.org/html/2610.12527#bib.bib13)\]\. For system operators, these results are most useful when the error number is tied to the operating setting in which the visibility estimate will be trusted: the same customers next month, new customers in the same distribution region, or a different region with only a few locally instrumented households\. A random timestamp split within the same households evaluates interpolation within familiar customer histories, leaving new\-customer and future\-period deployment risk unmeasured\. PV\-disaggregation studies would therefore benefit from reporting the operating regime behind the error number\.
We use established sequence models as instruments to answer an operational question: how much PV visibility can a distribution operator expect for the customers, periods, and regions on which a model will actually be used, and which levers improve it? We evaluate six sequence models under four deployment regimes that separate household transfer from temporal extrapolation on Ausgrid, with cross\-dataset adaptation to Pecan Street\. Our findings are:
- •Known\-customer accuracy substantially understates new\-customer error\. Under identical future conditions on Ausgrid, daylight mean absolute error \(MAE\) of the best model rises from 0\.104 kW on customers seen during development to 0\.185 kW on customers outside the training population\.
- •Deployment setting dominates model choice in our experiments\. Across six modern sequence models under a fixed development practice, the deployment regime explains 78\.6% of the error variation in the tested grid and model family only 18\.0%\.
- •Limited target supervision substantially reduces transfer error\. Under target\-domain normalization, fine\-tuning an Ausgrid model on five Pecan Street reference households cuts source\-model transfer error by approximately 28%–36%, with rapidly saturating returns\.
- •The customer history a deployment needs appears use\-case dependent\. In our sweeps, longer input windows consistently improve estimates for known customers, while new\-customer results vary by model\.
## IIRelated Work
Behind\-the\-meter PV disaggregation has been studied using physical and proxy\-based methods, statistical models, and deep learning\. Physical and proxy approaches use irradiance reference signals, clear\-sky models, or PV capacity estimates to reconstruct generation\[[10](https://arxiv.org/html/2610.12527#bib.bib4),[11](https://arxiv.org/html/2610.12527#bib.bib8),[12](https://arxiv.org/html/2610.12527#bib.bib9)\]\. These methods are attractive because they encode solar physics, but they can require proxy systems, capacity information, or assumptions about orientation and shading that are often unavailable for residential customers\. Learned approaches estimate PV generation directly from net\-load and auxiliary features\. Recent work includes convolutional neural network\-bidirectional long short\-term memory \(CNN\-BiLSTM\) models\[[3](https://arxiv.org/html/2610.12527#bib.bib3)\], graph and graph\-recurrent formulations\[[13](https://arxiv.org/html/2610.12527#bib.bib2),[4](https://arxiv.org/html/2610.12527#bib.bib6),[8](https://arxiv.org/html/2610.12527#bib.bib12)\], cross\-iteration refinement\[[5](https://arxiv.org/html/2610.12527#bib.bib7)\], diffusion models\[[6](https://arxiv.org/html/2610.12527#bib.bib10)\], and transfer\-oriented long short\-term memory \(LSTM\) variants\[[7](https://arxiv.org/html/2610.12527#bib.bib11)\]\.
We assess whether reported errors answer deployment\-relevant visibility questions\. Table[I](https://arxiv.org/html/2610.12527#S2.T1)audits recent PV\-disaggregation papers against the regimes defined in Section[III](https://arxiv.org/html/2610.12527#S3)\. Many papers report a percentage split without sufficient detail to identify whether households or time periods overlap between training and testing\. Where the split is clear, most studies evaluate on seen households or single deployment regimes\. As a result, similar reported MAE values may correspond to different operational uses of the same smart\-meter analytics pipeline\.
Similar concerns have been raised in non\-intrusive load monitoring, where held\-out\-house and cross\-dataset transfer are important for scalable deployment\[[14](https://arxiv.org/html/2610.12527#bib.bib14)\]\. PV disaggregation is affected by the same issue, but with additional physical structure from irradiance and diurnal PV shape\. We therefore position the present work as an operational\-regime analysis for distribution\-grid visibility that complements architectural work in PV disaggregation\.
TABLE I:Audit of deployment\-regime reporting in residential PV disaggregation literature\. ✓ indicates the regime is used;??indicates insufficient household/time\-overlap detail; CD denotes cross\-dataset transfer\.
## IIIDistribution\-Grid Visibility Problem and Deployment Regimes
### III\-APV Visibility from Net Measurements
For each householdiiand timett, the observed net\-load signal is
ni,t=ci,t−gi,t,ci,t≥0,gi,t≥0,n\_\{i,t\}=c\_\{i,t\}\-g\_\{i,t\},\\quad c\_\{i,t\}\\geq 0,\\;g\_\{i,t\}\\geq 0,\(1\)whereci,tc\_\{i,t\}is gross consumption andgi,tg\_\{i,t\}is PV generation\. The auxiliary solar\-weather channels are global horizontal irradiance \(GHI\), direct normal irradiance \(DNI\), diffuse horizontal irradiance \(DHI\), solar zenith angle \(SZA\), and ambient temperatureTT\. For each household, a training sample consists of a length\-WWwindow
𝐱i,s:s\+W−1=\[n,GHI,DNI,DHI,SZA,T\]i,s:s\+W−1\.\\mathbf\{x\}\_\{i,s:s\+W\-1\}=\[n,\\mathrm\{GHI\},\\mathrm\{DNI\},\\mathrm\{DHI\},\\mathrm\{SZA\},T\]\_\{i,s:s\+W\-1\}\.\(2\)The model predicts a corresponding PV\-generation sequence,
𝐠^i,s:s\+W−1=fθ\(𝐱i,s:s\+W−1\)\.\\hat\{\\mathbf\{g\}\}\_\{i,s:s\+W\-1\}=f\_\{\\theta\}\(\\mathbf\{x\}\_\{i,s:s\+W\-1\}\)\.\(3\)
At evaluation, the model receives a completeWW\-step data window before estimating PV for timestamps within that window\. The reported evaluation is therefore retrospective and non\-causal\.
We measure PV\-visibility error using daylight MAE in denormalized kW,
MAEday=∑i,tmi,t\|g^i,t−gi,t\|∑i,tmi,t,mi,t=𝟙\{SZAi,t≤88∘\}\.\\operatorname\{MAE\}\_\{\\mathrm\{day\}\}=\\frac\{\\sum\_\{i,t\}m\_\{i,t\}\\left\|\\hat\{g\}\_\{i,t\}\-g\_\{i,t\}\\right\|\}\{\\sum\_\{i,t\}m\_\{i,t\}\},\\quad m\_\{i,t\}=\\mathbb\{1\}\\\{\\mathrm\{SZA\}\_\{i,t\}\\leq 88^\{\\circ\}\\\}\.\(4\)
### III\-BOperational Deployment Regimes
Four regimes cross household familiarity and time period, as shown in Fig\.[2](https://arxiv.org/html/2610.12527#S3.F2)and Table[II](https://arxiv.org/html/2610.12527#S3.T2)\. The central operational comparison in this paper is S2 versus S4: both use the same final test period, but S2 represents future visibility for known customers whereas S4 represents future visibility for customers absent from model development\.
Fig\. 2:Deployment\-regime matrix\. The regimes separate household transfer from temporal extrapolation\. S2 and S4 share the final 183\-day test period, isolating the effect of household familiarity\.TABLE II:Deployment regimes\. S3 uses held\-out households over the pre\-test period and is used as a household\-transfer diagnostic\.For Ausgrid, 20% of households are held out by split seed, yielding 239 seen and 60 unseen households\. The final 183 days form the future test period for S2 and S4\. S1 uses held\-out calendar days from seen households in the pre\-test period, while S3 uses held\-out households in the pre\-test period\. The validation set is drawn from the pre\-test period on seen households only and is used for early stopping and hyperparameter selection\. To avoid temporal\-window leakage, the split generator rejects any train, validation, or test sample whose input or output window crosses the corresponding split boundary\. Held\-out households are not used for training, validation, early stopping, or normalization statistics\.
## IVStudy Design
### IV\-ADatasets and Features
We evaluate primarily on the Ausgrid Solar Home Electricity Dataset\[[16](https://arxiv.org/html/2610.12527#bib.bib16)\]\. The original dataset reports consumption and PV generation separately for 300 residential customers in the Ausgrid distribution network around Sydney, Australia, recorded at 30\-minute resolution\. Our filtered panel contains 299 customers, and the net\-load input is synthesized as consumption minus gross PV generation\. After filtering, the Ausgrid study window spans January 2011 to June 2013\. For cross\-dataset transfer, we use Pecan Street\[[17](https://arxiv.org/html/2610.12527#bib.bib17)\], comprising 17 Austin, Texas households at 30\-minute resolution over one year\. Solar\-weather features are aligned to smart\-meter timestamps from NSRDB\[[18](https://arxiv.org/html/2610.12527#bib.bib15)\]\. Evaluation uses historical gridded weather estimates derived from satellite observations and physical models\. Operational forecasts are outside the scope of this evaluation\. Ausgrid feature normalizers are fit on the training portion of seen households\. Pecan Street target\-domain normalization uses the 14 non\-evaluation households in each split\.
### IV\-BVisibility Models and Training Contract
We evaluate six deep sequence models: CNN\-BiLSTM\[[3](https://arxiv.org/html/2610.12527#bib.bib3)\], temporal convolutional network \(TCN\)\[[19](https://arxiv.org/html/2610.12527#bib.bib22)\], Temporal Fusion Transformer \(TFT\)\[[20](https://arxiv.org/html/2610.12527#bib.bib21)\], TimesNet\[[21](https://arxiv.org/html/2610.12527#bib.bib20)\], Mamba\[[22](https://arxiv.org/html/2610.12527#bib.bib19)\], and PatchTST\[[23](https://arxiv.org/html/2610.12527#bib.bib18)\]\. All models receive the same six input channels\.
All deep models are trained under a fixed contract\. Hyperparameters are selected by a 10\-trial random search on the Ausgrid S1 validation split at fixedW=96W=96, then frozen and applied unchanged to all regimes\. This single\-contract setting applies the same visibility\-model development practice to every regime, including S4\. Neural models use AdamW, cosine learning\-rate scheduling with linear warmup, early stopping on validation daylight MAE, non\-negativity via softplus output, and zero\-clamping at night\.
For the main Ausgrid comparison,WWis fixed to 96 half\-hourly steps \(48 hours\)\. The training loss is daylight MAE plus an integrated PV\-energy penalty\. BecauseWWis fixed in this experiment, the energy term is comparable across regimes and models\. For the context\-length sweep, whereWWchanges, we use a window\-normalized energy loss:
L=MAEday\+λE\|1\|𝒲d\|∑t∈𝒲dg^t−1\|𝒲d\|∑t∈𝒲dgt\|,L=\\operatorname\{MAE\}\_\{\\mathrm\{day\}\}\+\\lambda\_\{E\}\\left\|\\frac\{1\}\{\|\\mathcal\{W\}\_\{d\}\|\}\\sum\_\{t\\in\\mathcal\{W\}\_\{d\}\}\\hat\{g\}\_\{t\}\-\\frac\{1\}\{\|\\mathcal\{W\}\_\{d\}\|\}\\sum\_\{t\\in\\mathcal\{W\}\_\{d\}\}g\_\{t\}\\right\|,\(5\)where𝒲d\\mathcal\{W\}\_\{d\}is the daylight subset of the prediction window\. The coefficientλE=0\.35\\lambda\_\{E\}=0\.35remains fixed from the main validation setting across context lengths\. The term discourages window\-level PV\-energy bias while preventing the regularization magnitude from increasing mechanically withWW\.
Across five Pecan Street splits, three households are evaluated over 2 July–31 December 2018 andk∈\{1,3,5,10\}k\\in\\\{1,3,5,10\\\}disjoint reference households are drawn from the remaining 14\. The model is fine\-tuned on their full 2018 records for 20 epochs \(AdamW; 0\.1 times the source learning rate; weight decay10−410^\{\-4\}; batch size 32;W=96W=96; stride 24; gradient clipping 1\.0\), requiring approximately 420–4460 updates per split on an AMD RX 7900 XTX\. The target\-normalized source\-model case applies the Ausgrid weights directly; reference\-household gradient updates occur in the adaptation cases\.
### IV\-CUncertainty and Reproducibility
Ausgrid results are averaged over five household splits; 95% BCa intervals are computed by bootstrapping households \(B=1000B=1000\)\. Pecan Street results report mean and 95%ttintervals over five target\-household splits \(three evaluation households per split; 10 unique\), summarizing split\-to\-split variability\. Table[III](https://arxiv.org/html/2610.12527#S4.T3)gives further details\.
TABLE III:Reproducibility summary\.
## VResults and Discussion
### V\-AAusgrid: New\-Customer Visibility Error is Much Higher
Table[IV](https://arxiv.org/html/2610.12527#S5.T4)and Fig\.[3](https://arxiv.org/html/2610.12527#S5.F3)report daylight MAE at fixedW=96W=96\. The main operational observation is that visibility error changes substantially when the same analytics pipeline is moved from known customers to unseen customers\. For example, CNN\-BiLSTM increases from 0\.104 kW under S2 to 0\.185 kW under S4, and TCN increases from 0\.111 kW to 0\.188 kW\.
The seen\-household regimes also reveal period\-composition effects\. S2 is lower than S1 for most models, even though S1 is an interpolation setting, which suggests that seasonal and irradiance differences between held\-out pre\-test days and the final 183\-day period influence absolute MAE\. The main deployment comparison therefore centers on S2 versus S4, which share the same final test period and isolate the effect of household familiarity\.
Fig\. 3:Ausgrid daylight MAE across deployment regimes\. New\-customer regimes produce substantially higher PV\-visibility errors than known\-customer regimes, while the leading visibility models remain close within each regime\.TABLE IV:Ausgrid daylight PV\-visibility error, measured as MAE \(kW\) atW=96W=96, mean over five house\-split seeds with 95% BCa bootstrap CIs over households\. Bold marks the best performing model per regime\.To make this comparison precise, letya,ry\_\{a,r\}denote the mean daylight MAE of model familya=1,…,Aa=1,\\ldots,Aunder regimer=1,…,Rr=1,\\ldots,R, and decompose the cell\-mean variation as
ya,r=μ\+αa\+βr\+ϵa,r,y\_\{a,r\}=\\mu\+\\alpha\_\{a\}\+\\beta\_\{r\}\+\\epsilon\_\{a,r\},\(6\)whereαa\\alpha\_\{a\}andβr\\beta\_\{r\}are model\-family and regime main effects\. Attributing the total sum of squares of theA=6A=6byR=4R=4grid to these effects in the standard two\-way manner, Fig\.[4](https://arxiv.org/html/2610.12527#S5.F4)shows that deployment regime accounts for 78\.6% of the variation, model family for 18\.0%, and residual interaction for 3\.4%\. Under this fixed hyperparameter\-search budget and training contract, where the PV\-visibility estimate is deployed changes the error far more than the choice among the leading visibility models\. For a utility procuring or developing PV\-visibility analytics, this suggests that the data regime the system will face deserves at least as much scrutiny as model choice\.
Fig\. 4:Descriptive variance decomposition of the deep\-model MAE grid\. Under the fixed training contract, deployment regime explains the largest share of cell\-mean variation\.A rank\-level analysis refines this guidance\. Ranking the model families by mean MAE within S1 and within S4, the two orderings remain highly correlated \(Spearmanρs≈0\.90\\rho\_\{s\}\\approx 0\.90, Kendallτa≈0\.80\\tau\_\{a\}\\approx 0\.80\)\. Convenient known\-customer tests therefore remain useful for coarse model screening before deployment; deployment\-error levels still require regime\-matched evaluation\. Planning studies, hosting\-capacity assessments, and demand\-response baselines that rely on PV\-visibility estimates for uninstrumented customers should budget against S4\-type error, which is nearly twice the known\-customer figure in our experiments\.
### V\-BTarget\-Region Fine\-Tuning Improves Cross\-Region Transfer
Table[V](https://arxiv.org/html/2610.12527#S5.T5)reports results for the target\-normalized source model and adaptations usingk∈\{1,3,5,10\}k\\in\\\{1,3,5,10\\\}reference households\. Cross\-region distribution and seasonal shifts raise error above Ausgrid S4\. Atk=5k=5, every model’s source\-model MAE falls by 28%–36%, with a best MAE of 0\.353 kW\.
TABLE V:Ausgrid→\\toPecan Street daylight MAE \(kW\), mean \[95%ttinterval\] over five target\-household selection splits\. Fine\-tuning and evaluation households are disjoint within every split\. Bold marks the best model per column\.Gains saturate quickly: moving fromk=1k=1tok=5k=5consistently helps, whereask=10k=10adds little\. For TCN, the paired reduction from the source model tok=5k=5is 0\.202 kW \[95%ttinterval: 0\.129–0\.275 kW\]\. Larger target datasets would improve precision\.
### V\-COperational Value of Historical Context
Fig\. 5:Context\-length sensitivity under S2 and S4\. Long retrospective context consistently improves known\-customer temporal extrapolation, whereas new\-customer deployment performance is flatter and model\-dependent\.Many prior PV\-disaggregation studies adopt a one\-day window because it matches a daily\-profile formulation\[[3](https://arxiv.org/html/2610.12527#bib.bib3)\],\[[4](https://arxiv.org/html/2610.12527#bib.bib6)\],\[[6](https://arxiv.org/html/2610.12527#bib.bib10)\],\[[9](https://arxiv.org/html/2610.12527#bib.bib13)\]\. From an operations perspective, context length controls how much recent customer history is required before a visibility estimate can be produced\. We evaluate context\-length sensitivity across deployment regimes by sweepingW∈\{24,48,96,192\}W\\in\\\{24,48,96,192\\\}under the normalized objective in \([5](https://arxiv.org/html/2610.12527#S4.E5)\)\. To make context lengths comparable, MAE is recomputed on theW=192W=192\-compatible test timestamp support\. This window\-normalized analysis covers three household split seeds and the five models shown in Fig\.[5](https://arxiv.org/html/2610.12527#S5.F5)\. Its purpose is to compare trends across context lengths; the absolute MAE values differ from Table[IV](https://arxiv.org/html/2610.12527#S5.T4)because the sweep uses fewer split seeds, a different loss normalization, and restricted timestamp support\.
TABLE VI:Summary of the context\-length sweep\.Δ192−24\\Delta\_\{192\-24\}is the MAE atW=192W=192minus the MAE atW=24W=24\. Negative values indicate improvement from longer context\.Fig\.[5](https://arxiv.org/html/2610.12527#S5.F5)and Table[VI](https://arxiv.org/html/2610.12527#S5.T6)show a clear asymmetry\. Under S2, all five models achieve their best mean MAE atW=192W=192, with improvements fromW=24W=24ranging from 0\.0146 to 0\.0346 kW\. Long retrospective context is consistently useful when the household is familiar but the time period is future\. Under S4, context preferences vary by model class: CNN\-BiLSTM and TimesNet favorW=48W=48, TCN favorsW=96W=96, TFT favorsW=24W=24, and Mamba favorsW=192W=192\. The S4 differences are also smaller and less stable than the S2 gains\.
Long retrospective context likely contains household\-specific behavioral and PV\-system signatures\. These signatures are useful under S2, where the household has been observed during training, and less reliable under S4, where the household is unseen\. These results suggest an operational mapping\. For retrospective analytics on known customers, such as settlement, demand\-response baseline construction, and hosting\-capacity studies over an instrumented cohort, supplying several days of history was consistently beneficial in our sweep\. New\-customer responses varied by model, allowing window size to follow data\-availability and latency constraints\.
### V\-DData Quality and Deployment Considerations
The experiments use cleaned, synchronized 30\-minute records\. Future work will quantify sensitivity to outages, delays, misalignment, and measurement noise\. Online deployment also requires causal windows, inference\-time weather, and testing under representative faults\.
## VIConclusion
This paper studied behind\-the\-meter PV disaggregation as a distribution\-grid visibility problem\. Visibility error budgets should be regime\-matched: error nearly doubled when models served customers outside the training population, while known\-customer tests remained useful for coarse model screening\. Fine\-tuning on a small, household\-disjoint target cohort recovered most of the observed adaptation gain, subject to validation on larger datasets\. Long input windows improved known\-customer estimates; context\-length effects for new customers varied by model\. PV\-visibility results should therefore report deployment regime, leakage\-safe splits, and household\-level uncertainty\.
## References
- \[1\]\(2021\)Exploring blockchain for the coordination of distributed energy resources\.In2021 55th Annual Conference on Information Sciences and Systems \(CISS\),pp\. 1–6\.Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p1.1)\.
- \[2\]IEA\(2025\)Renewables 2025\.IEA,Paris\.Note:Licence: CC BY 4\.0External Links:[Link](https://www.iea.org/reports/renewables-2025)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p1.1)\.
- \[3\]J\. Zhang, Z\. Tan, J\. Tian, K\. Li, and J\. Zhang\(2024\)Distributed photovoltaic power disaggregation based on deep learning\.In2024 9th Asia Conference on Power and Electrical Engineering \(ACPEE\),pp\. 1293–1297\.External Links:[Link](http://dx.doi.org/10.1109/ACPEE60788.2024.10532594),[Document](https://dx.doi.org/10.1109/acpee60788.2024.10532594)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p3.1),[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.3.1.1.1),[§II](https://arxiv.org/html/2610.12527#S2.p1.1),[§IV\-B](https://arxiv.org/html/2610.12527#S4.SS2.p1.1),[§V\-C](https://arxiv.org/html/2610.12527#S5.SS3.p1.1)\.
- \[4\]M\. Khodayar, A\. F\. Bavil, and M\. Saffari\(2024\)Sparse attention graph gated recurrent unit for spatiotemporal behind\-the\-meter load and pv disaggregation\.In2024 16th International Conference on Electronics, Computers and Artificial Intelligence \(ECAI\),pp\. 1–6\.External Links:[Link](http://dx.doi.org/10.1109/ECAI61503.2024.10607573),[Document](https://dx.doi.org/10.1109/ecai61503.2024.10607573)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p3.1),[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.5.1.1.1),[§II](https://arxiv.org/html/2610.12527#S2.p1.1),[§V\-C](https://arxiv.org/html/2610.12527#S5.SS3.p1.1)\.
- \[5\]K\. Pan, Z\. Chen, C\. S\. Lai, C\. Xie, D\. Wang, Z\. Zhao, X\. Wu, N\. Tong, L\. Lei Lai, and N\. D\. Hatziargyriou\(2022\)A novel data\-driven method for behind\-the\-meter solar generation disaggregation with cross\-iteration refinement\.IEEE Transactions on Smart Grid13\(5\),pp\. 3823–3835\.External Links:ISSN 1949\-3061,[Link](http://dx.doi.org/10.1109/TSG.2022.3171656),[Document](https://dx.doi.org/10.1109/tsg.2022.3171656)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p3.1),[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.6.1.1.1),[§II](https://arxiv.org/html/2610.12527#S2.p1.1)\.
- \[6\]M\. Jené\-Vinuesa, H\. Kazmi, M\. Aragüés\-Peñalba, and A\. Sumper\(2026\)Conditional diffusion modeling for probabilistic behind\-the\-meter pv disaggregation\.Energy and AI24,pp\. 100692\.External Links:ISSN 2666\-5468,[Document](https://dx.doi.org/https%3A//doi.org/10.1016/j.egyai.2026.100692),[Link](https://www.sciencedirect.com/science/article/pii/S2666546826000182)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p3.1),[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.7.1.1.1),[§II](https://arxiv.org/html/2610.12527#S2.p1.1),[§V\-C](https://arxiv.org/html/2610.12527#S5.SS3.p1.1)\.
- \[7\]C\. Zhang, H\. Long, Z\. Zhang, and J\. Cao\(2026\)Practicality\-enhanced behind\-the\-meter pv power generation disaggregation based on synchronization and transferability fused lstm framework\.Energy and AI23,pp\. 100675\.External Links:ISSN 2666\-5468,[Document](https://dx.doi.org/https%3A//doi.org/10.1016/j.egyai.2026.100675),[Link](https://www.sciencedirect.com/science/article/pii/S2666546826000017)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p3.1),[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.8.1.1.1),[§II](https://arxiv.org/html/2610.12527#S2.p1.1)\.
- \[8\]L\. Helwani, T\. Alskaif, and W\. Sark\(2025\)Dynamic graph neural networks for uncertainty\-aware residential photovoltaic power and load disaggregation\.pp\. 1–5\.External Links:[Document](https://dx.doi.org/10.1109/ISGTEurope64741.2025.11305351)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p3.1),[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.9.1.1.1),[§II](https://arxiv.org/html/2610.12527#S2.p1.1)\.
- \[9\]X\. Chen, C\. Huang, Y\. Zhang, and H\. Wang\(2024\)Season\-independent pv disaggregation using multi\-scale net load temporal feature extraction and weather factor fusion\.In2024 IEEE 8th Conference on Energy Internet and Energy System Integration \(EI2\),Vol\.,pp\. 850–855\.External Links:[Document](https://dx.doi.org/10.1109/EI264398.2024.10990379)Cited by:[§I](https://arxiv.org/html/2610.12527#S1.p3.1),[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.10.1.1.1),[§V\-C](https://arxiv.org/html/2610.12527#S5.SS3.p1.1)\.
- \[10\]D\. Chen and D\. Irwin\(2017\)SunDance: black\-box behind\-the\-meter solar disaggregation\.InProceedings of the Eighth International Conference on Future Energy Systems,e\-Energy ’17,pp\. 45–55\.External Links:[Link](http://dx.doi.org/10.1145/3077839.3077848),[Document](https://dx.doi.org/10.1145/3077839.3077848)Cited by:[§II](https://arxiv.org/html/2610.12527#S2.p1.1)\.
- \[11\]K\. Li, F\. Wang, Z\. Mi, M\. Fotuhi\-Firuzabad, N\. Duić, and T\. Wang\(2019\)Capacity and output power estimation approach of individual behind\-the\-meter distributed photovoltaic system for demand response baseline estimation\.Applied Energy253,pp\. 113595\.External Links:ISSN 0306\-2619,[Link](http://dx.doi.org/10.1016/j.apenergy.2019.113595),[Document](https://dx.doi.org/10.1016/j.apenergy.2019.113595)Cited by:[§II](https://arxiv.org/html/2610.12527#S2.p1.1)\.
- \[12\]F\. Kabir, N\. Yu, W\. Yao, R\. Yang, and Y\. Zhang\(2019\)Estimation of behind\-the\-meter solar generation by integrating physical with statistical models\.In2019 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids \(SmartGridComm\),pp\. 1–6\.External Links:[Link](http://dx.doi.org/10.1109/SmartGridComm.2019.8909743),[Document](https://dx.doi.org/10.1109/smartgridcomm.2019.8909743)Cited by:[§II](https://arxiv.org/html/2610.12527#S2.p1.1)\.
- \[13\]M\. Saffari, M\. Khodayar, M\. E\. Khodayar, and M\. Shahidehpour\(2024\)Behind\-the\-meter load and pv disaggregation via deep spatiotemporal graph generative sparse coding with capsule network\.IEEE Transactions on Neural Networks and Learning Systems35\(10\),pp\. 14573–14587\.External Links:ISSN 2162\-2388,[Link](http://dx.doi.org/10.1109/TNNLS.2023.3280078),[Document](https://dx.doi.org/10.1109/tnnls.2023.3280078)Cited by:[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.2.1.1.1),[§II](https://arxiv.org/html/2610.12527#S2.p1.1)\.
- \[14\]D\. Murray, L\. Stankovic, V\. Stankovic, S\. Lulic, and S\. Sladojevic\(2019\)Transferability of neural network approaches for low\-rate energy disaggregation\.InICASSP 2019 \- 2019 IEEE International Conference on Acoustics, Speech and Signal Processing \(ICASSP\),Vol\.,pp\. 8330–8334\.External Links:[Document](https://dx.doi.org/10.1109/ICASSP.2019.8682486),ISSN 2379\-190XCited by:[§II](https://arxiv.org/html/2610.12527#S2.p3.1)\.
- \[15\]N\. A\. Khafaf, B\. McGrath, S\.M\. N\. Ali, and M\. Jalili\(2024\)Artificial neural network for disaggregation of behind\-the\-meter energy consumption and generation\.In2024 IEEE 22nd International Conference on Industrial Informatics \(INDIN\),pp\. 1–6\.External Links:[Link](http://dx.doi.org/10.1109/INDIN58382.2024.10774215),[Document](https://dx.doi.org/10.1109/indin58382.2024.10774215)Cited by:[TABLE I](https://arxiv.org/html/2610.12527#S2.T1.1.4.1.1.1)\.
- \[16\]E\. L\. Ratnam, S\. R\. Weller, C\. M\. Kellett, and A\. T\. Murray\(2017\)Residential load and rooftop pv generation: an australian distribution network dataset\.International Journal of Sustainable Energy36\(8\),pp\. 787–806\.External Links:[Document](https://dx.doi.org/10.1080/14786451.2015.1100196),[Link](https://doi.org/10.1080/14786451.2015.1100196),https://doi\.org/10\.1080/14786451\.2015\.1100196Cited by:[§IV\-A](https://arxiv.org/html/2610.12527#S4.SS1.p1.1)\.
- \[17\]C\. Holcomb\(2012\)Pecan street inc\.: a test\-bed for nilm\.InInternational Workshop on Non\-Intrusive Load Monitoring, Pittsburgh, PA, USA,Vol\.1\.Cited by:[§IV\-A](https://arxiv.org/html/2610.12527#S4.SS1.p1.1)\.
- \[18\]M\. Sengupta, Y\. Xie, A\. Lopez, A\. Habte, G\. Maclaurin, and J\. Shelby\(2018\)The national solar radiation data base \(nsrdb\)\.Renewable and Sustainable Energy Reviews89,pp\. 51–60\.External Links:ISSN 1364\-0321,[Document](https://dx.doi.org/https%3A//doi.org/10.1016/j.rser.2018.03.003),[Link](https://www.sciencedirect.com/science/article/pii/S136403211830087X)Cited by:[§IV\-A](https://arxiv.org/html/2610.12527#S4.SS1.p1.1)\.
- \[19\]S\. Bai, J\. Z\. Kolter, and V\. Koltun\(2018\)An empirical evaluation of generic convolutional and recurrent networks for sequence modeling\.External Links:1803\.01271,[Link](https://arxiv.org/abs/1803.01271)Cited by:[§IV\-B](https://arxiv.org/html/2610.12527#S4.SS2.p1.1)\.
- \[20\]B\. Lim, S\. Ö\. Arık, N\. Loeff, and T\. Pfister\(2021\)Temporal fusion transformers for interpretable multi\-horizon time series forecasting\.International Journal of Forecasting37\(4\),pp\. 1748–1764\.External Links:ISSN 0169\-2070,[Document](https://dx.doi.org/https%3A//doi.org/10.1016/j.ijforecast.2021.03.012),[Link](https://www.sciencedirect.com/science/article/pii/S0169207021000637)Cited by:[§IV\-B](https://arxiv.org/html/2610.12527#S4.SS2.p1.1)\.
- \[21\]H\. Wu, T\. Hu, Y\. Liu, H\. Zhou, J\. Wang, and M\. Long\(2023\)TimesNet: temporal 2d\-variation modeling for general time series analysis\.External Links:2210\.02186,[Link](https://arxiv.org/abs/2210.02186)Cited by:[§IV\-B](https://arxiv.org/html/2610.12527#S4.SS2.p1.1)\.
- \[22\]A\. Gu and T\. Dao\(2024\)Mamba: linear\-time sequence modeling with selective state spaces\.External Links:2312\.00752,[Link](https://arxiv.org/abs/2312.00752)Cited by:[§IV\-B](https://arxiv.org/html/2610.12527#S4.SS2.p1.1)\.
- \[23\]Y\. Nie, N\. H\. Nguyen, P\. Sinthong, and J\. Kalagnanam\(2023\)A time series is worth 64 words: long\-term forecasting with transformers\.External Links:2211\.14730,[Link](https://arxiv.org/abs/2211.14730)Cited by:[§IV\-B](https://arxiv.org/html/2610.12527#S4.SS2.p1.1)\.相似文章
从智能电表数据揭示住宅PV-EV共同采用:负载原型与检测用于需求侧规划
本文提出一个集成工作流,利用智能电表数据聚类负载曲线,并使用机器学习模型检测PV/EV共同采用,以辅助需求侧规划和网络管理。
一种用于稳健多时间尺度光伏功率预测的 TFT-NBEATS 混合框架
本文提出一种融合 Temporal Fusion Transformer 与 N-BEATS 的注意力混合框架,用于统一多时间尺度的光伏功率预测,在 DKASC 真实数据集上相比最佳基线 TFT 实现 35–40% 的 RMSE 降低。
基于学习型控制变量的电动汽车充电站罕见电网停电概率估计
一篇提出利用机器学习分类器构建学习型控制变量的论文,旨在降低电动汽车充电负荷罕见电网停电概率估计中的方差。研究表明,提升树模型可消除约60%的方差,并为泗水配电网络的停电日规划提供了改进。
智能电表能源预测的深度时间序列模型实证基准测试
本文对九种深度学习模型在智能电表数据上的能源预测进行了基准测试,揭示了随着历史输入的增加,准确率会饱和;随着预测时间范围的延长,准确率下降;轻量级模型提供了成本效益高的替代方案。
美国电网制约:到2028年或将实现40GW以上的表后数据中心?
本文分析了美国电网容量制约因素,并对必须由表后电力解决方案填补的数据中心缺口进行建模,预计到2028年将超过40GW。